Trane Furnace Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 40 codes covered.
Shop Trane Furnace parts at RepairClinic or Amazon
All Furnace codes across brands →
Not sure of the code? Tap along with it
If your Trane Furnace blinks or beeps a pattern instead of showing a code, tap the button in time with each blink or beep. A pause longer than a second and a half starts a new group - we will match the rhythm to a code.
Your rhythm: -
Finding your model number: it is inside the blower/burner compartment door.
S-series seven-segment display — S8V2
All Trane S-series seven-segment display — S8V2 codes & guides → (1 covered)
- E4.2 — On Trane S8V2 furnaces only, code E4.2 means the roll-out limit switch is open — flame has rolled out of the burner compartment or the…
S-series seven-segment display — S8V2/S9V2-VS
All Trane S-series seven-segment display — S8V2/S9V2-VS codes & guides → (1 covered)
- E17 — On Trane S8V2 and S9V2-VS furnaces, code E17 means a blower communication error — the blower motor is not responding to the control (worded…
S-series seven-segment display — S9V2-VS
All Trane S-series seven-segment display — S9V2-VS codes & guides → (2 covered)
- E06 — On Trane S9V2-VS furnaces only, code E06 combines two electrical faults: line voltage polarity reversed or bad grounding. Other S-series…
- E10 — On Trane S9V2-VS furnaces, code E10 means the inducer motor gave no communication response — a communication failure between the control's…
S-series seven-segment display — S9X1/S9X2/S9B1
All Trane S-series seven-segment display — S9X1/S9X2/S9B1 codes & guides → (1 covered)
- E09 — On Trane S9X1, S9X2 and S9B1 furnaces (not listed for S8X1/S8X2), code E09 means an open inducer limit switch or condensate pressure switch.
S-series seven-segment display — S9X1/S9X2/S9B1/S8X1/S8X2
All Trane S-series seven-segment display — S9X1/S9X2/S9B1/S8X1/S8X2 codes & guides → (14 covered)
- E01 — On Trane S-series furnaces with a seven-segment display (S9X1, S9X2, S9B1 and S8X1, S8X2), code E01 means an internal integrated furnace…
- E04 — On Trane S-series furnaces with a seven-segment display (S9X1, S9X2, S9B1 and S8X1, S8X2), code E04 means an open limit — the main thermal…
- E05 — On Trane S-series furnaces with a seven-segment display (S9X1, S9X2, S9B1 and S8X1, S8X2), code E05 means flame was detected when it should…
- E08 — On Trane S-series furnaces with a seven-segment display (S9X1, S9X2, S9B1 and S8X1, S8X2), code E08 means flame current is low but still…
- E11 — On Trane S-series furnaces with a seven-segment display (S9X1, S9X2, S9B1 and S8X1, S8X2), code E11 is a gas valve fault group — most…
- E12 — On Trane S-series furnaces with a seven-segment display (S9X1, S9X2, S9B1 and S8X1, S8X2), code E12 means an open fuse — the low-voltage…
- E2.1 — On Trane S-series furnaces with a seven-segment display (S9X1, S9X2, S9B1 and S8X1, S8X2), code E2.1 is retry lockout — flame was never…
- E2.2 — On Trane S-series furnaces with a seven-segment display (S9X1, S9X2, S9B1 and S8X1, S8X2), code E2.2 is recycles exceeded — flame was…
- E3.1 — On Trane S-series furnaces with a seven-segment display (S9X1, S9X2, S9B1 and S8X1, S8X2), code E3.1 means the first-stage pressure switch…
- E3.2 — On Trane S-series furnaces with a seven-segment display (S9X1, S9X2, S9B1 and S8X1, S8X2), code E3.2 means the first-stage pressure switch…
- E6.1 — On Trane S-series furnaces with a seven-segment display (S9X1, S9X2, S9B1 and S8X1, S8X2), code E6.1 means line voltage polarity is…
- E6.2 — On Trane S-series furnaces with a seven-segment display (S9X1, S9X2, S9B1 and S8X1, S8X2), code E6.2 means bad grounding — the control does…
- E6.3 — On Trane S-series furnaces with a seven-segment display (S9X1, S9X2, S9B1 and S8X1, S8X2), code E6.3 means an igniter fault — the igniter…
- E7.1 — On Trane S-series furnaces with a seven-segment display (S9X1, S9X2, S9B1 and S8X1, S8X2), code E7.1 means the first-stage gas valve is…
S-series seven-segment display — two-stage S9X2/S8X2
All Trane S-series seven-segment display — two-stage S9X2/S8X2 codes & guides → (1 covered)
- E3.4 — On two-stage Trane S-series furnaces with a seven-segment display (S9X2, S8X2), code E3.4 means the second-stage pressure switch is open —…
Single-stage IFC — XR80/XR90/XR95/XB80/XB90
All Trane Single-stage IFC — XR80/XR90/XR95/XB80/XB90 codes & guides → (10 covered)
- 2 flashes — On Trane single-stage furnaces (XR80, XR90, XR95, XB80, XB90 families) with the integrated furnace control (IFC), the red LED flashes 2…
- 3 flashes — On Trane single-stage furnaces (XR80, XR90, XR95, XB80, XB90 families) with the integrated furnace control (IFC), the red LED flashes 3…
- 4 flashes — On Trane single-stage furnaces (XR80, XR90, XR95, XB80, XB90 families) with the integrated furnace control (IFC), the red LED flashes this…
- 5 flashes — On Trane single-stage furnaces (XR80, XR90, XR95, XB80, XB90 families) with the integrated furnace control (IFC), the red LED flashes 5…
- 6 flashes — On Trane single-stage furnaces (XR80, XR90, XR95, XB80, XB90 families) with the integrated furnace control (IFC), the red LED flashes this…
- 7 flashes — On Trane single-stage furnaces (XR80, XR90, XR95, XB80, XB90 families) with the integrated furnace control (IFC), the red LED flashes 7…
- 8 flashes — On Trane single-stage furnaces (XR80, XR90, XR95, XB80, XB90 families) with the integrated furnace control (IFC), the red LED flashes this…
- 9 flashes — On Trane single-stage furnaces (XR80, XR90, XR95, XB80, XB90 families) using the replacement integrated furnace control covered in Trane…
- Fast flash — On Trane single-stage furnaces with the integrated furnace control, a fast red LED flash is normal operation with a call for heat present —…
- Slow flash — On Trane single-stage furnaces with the integrated furnace control, a slow red LED flash (about every 20 seconds) is normal operation with…
Two-stage IFC — XV80/XV90/XV95/XL80/XL90 (*UD2/*DD2)
All Trane Two-stage IFC — XV80/XV90/XV95/XL80/XL90 (*UD2/*DD2) codes & guides → (8 covered)
- 1 flash — On Trane two-stage furnaces (XV80, XV90, XV95, XL80, XL90 families, *UD2/*DD2) the green LED counts the fault: flame sensed when no flame…
- 10 flashes — On Trane two-stage furnaces (XV80, XV90, XV95, XL80, XL90 families, *UD2/*DD2) the green LED counts the fault: gas flow with no call for…
- 12 flashes — On Trane two-stage furnaces (XV80, XV90, XV95, XL80, XL90 families, *UD2/*DD2) the green LED counts the fault: igniter failure — the…
- 2 flashes — On Trane two-stage furnaces (XV80, XV90, XV95, XL80, XL90 families, *UD2/*DD2), the green LED flashes 2 times: a pressure switch stuck…
- 3 flashes — On Trane two-stage furnaces (XV80, XV90, XV95, XL80, XL90 families, *UD2/*DD2), the green LED flashes 3 times: the first-stage pressure…
- 5 flashes — On Trane two-stage furnaces (XV80, XV90, XV95, XL80, XL90 families, *UD2/*DD2), the green LED flashes 5 times: an open rollout switch or an…
- 7 flashes — On Trane two-stage furnaces (XV80, XV90, XV95, XL80, XL90 families, *UD2/*DD2), the green LED flashes 7 times: external lockout — retries…
- 9 flashes — On Trane two-stage furnaces (XV80, XV90, XV95, XL80, XL90 families, *UD2/*DD2), the green LED flashes 9 times: a grounding or…
Other codes & guides
- Continuous off — On Trane furnaces with the integrated furnace control, both LEDs continuously off means fuse open or no power reaching the control board.
- Continuous on — On Trane furnaces with the integrated furnace control, a red LED that stays continuously on (with the green LED also on) means internal…