Trane Furnace Single-stage IFC — XR80/XR90/XR95/XB80/XB90 5 flashes

What it should look like on your machine

then it repeats

5 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

On Trane single-stage furnaces (XR80, XR90, XR95, XB80, XB90 families) with the integrated furnace control (IFC), the red LED flashes 5 times: flame sensed when no flame should be present — the control sees a flame signal while the gas valve should be closed, which is a safety fault.

Likely causes

  1. Gas valve leaking or stuck open
  2. Shorted or damaged flame sensor wiring → Shop the flame sensor at RepairClinic
  3. Failed control board misreading the flame signal → Shop the control board at RepairClinic

How to fix it — step by step

  1. Turn the furnace power switch off and close the gas shutoff to the furnace
  2. Do not keep resetting or trying to run the furnace — this code is a safety fault — flame sensed with the gas valve closed is a safety fault → Shop the gas valve at RepairClinic
  3. If you smell gas, leave the house and call the gas utility from outside
  4. Call a technician to find the cause before the furnace runs again

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Trane manual is on Trane's support site — you'll need your model number.

Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.