What the E2.2 code means
On Trane S-series furnaces with a seven-segment display (S9X1, S9X2, S9B1 and S8X1, S8X2), code E2.2 is recycles exceeded — flame was sensed then lost repeatedly (one-hour lockout after 10 recycles).
Likely causes
- Dirty flame sensor dropping the flame signal
- Low or unstable gas pressure
- Dirty burners or poor burner ground
How to fix it — step by step
- Replace the air filter and open all registers
- Reset power once after the lockout and watch one full cycle
- Note whether the burners light and then go out within seconds
- Call a technician to clean/test the flame sensor and check gas pressure if it recurs → Shop the flame sensor at RepairClinic
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the flame sensor.
Parts that commonly fix the E2.2 code
- flame sensor - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Trane manual is on Trane's support site — you'll need your model number.
Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.
Related Trane Furnace S-series seven-segment display — S9X1/S9X2/S9B1/S8X1/S8X2 error codes
See all Trane S-series seven-segment display — S9X1/S9X2/S9B1/S8X1/S8X2 codes & guides →