Trane Furnace Single-stage IFC — XR80/XR90/XR95/XB80/XB90 8 flashes
What it should look like on your machine
then it repeats
8 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
On Trane single-stage furnaces (XR80, XR90, XR95, XB80, XB90 families) with the integrated furnace control (IFC), the red LED flashes this count: low flame sense signal — flame is present but the flame sensor signal is too weak for reliable operation.
Likely causes
- Dirty or oxidized flame sensor
- Poor burner ground
- Weak flame from dirty burners or low gas pressure
How to fix it — step by step
- Replace the air filter and confirm all registers are open
- Reset power once and observe whether the furnace completes a full heat cycle
- Note if the furnace lights then shuts off after a few seconds — a classic weak flame-signal pattern
- Call a technician to clean or replace the flame sensor and check burner ground; sensor cleaning is burner-compartment work → Shop the flame sensor at RepairClinic
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the flame sensor.
Parts that commonly fix it
- flame sensor - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Trane manual is on Trane's support site — you'll need your model number.
Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.
Related Trane Furnace Single-stage IFC — XR80/XR90/XR95/XB80/XB90 problems
See all Trane Single-stage IFC — XR80/XR90/XR95/XB80/XB90 codes & guides →