Trane Furnace Two-stage IFC — XV80/XV90/XV95/XL80/XL90 (*UD2/*DD2) 5 flashes
What it should look like on your machine
then it repeats
5 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
On Trane two-stage furnaces (XV80, XV90, XV95, XL80, XL90 families, *UD2/*DD2), the green LED flashes 5 times: an open rollout switch or an open control fuse.
Likely causes
- Flame rollout from a blocked or cracked heat exchanger
- Blocked venting causing a rollout trip
- Blown control board fuse from a low-voltage short → Shop the control board fuse at RepairClinic
How to fix it — step by step
- Turn the furnace power switch off and close the gas shutoff to the furnace
- Do not keep resetting or trying to run the furnace — this code is a safety fault — a tripped rollout switch can signal a dangerous heat exchanger problem → Shop the rollout switch at RepairClinic
- If you smell gas, leave the house and call the gas utility from outside
- Call a technician to find the cause before the furnace runs again
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the rollout switch.
Shop the rollout switch at RepairClinic or Amazon
Also tied to this fault: control board fuse - Shop at RepairClinic or Amazon
Parts that commonly fix it
- rollout switch - Shop at RepairClinic or Amazon
- control board fuse - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Trane manual is on Trane's support site — you'll need your model number.
Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.
Related Trane Furnace Two-stage IFC — XV80/XV90/XV95/XL80/XL90 (*UD2/*DD2) problems
See all Trane Two-stage IFC — XV80/XV90/XV95/XL80/XL90 (*UD2/*DD2) codes & guides →