Rinnai Water heater Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 58 codes covered.
Finding your model number: it is on the unit's rating plate.
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
All models
| Code | What it means | Check first | |
|---|---|---|---|
| 00 | Scale build-up in the heat exchanger - the same alert as LC in its maintenance-history form: Rinnai's… | Hard water scale build-up inside the heat exchanger | › |
| 03 | Power interruption during bath fill. Power was lost while a bath fill (MC-100V/BC-100V controller) was… | Power outage or interruption during a bath fill cycle | › |
| 05 | Bypass flow control device fault. The bypass flow control that blends cold water to temper the outlet is not… | Bypass flow control device failed | › |
| 10 | Air supply or exhaust blockage, or the condensate trap is full. The unit cannot move combustion air/exhaust… | Blocked condensate drain line or full condensate trap (condensing models) | › |
| 11 | No ignition. The heater tried to light and did not ignite (heater not turning on). | Gas turned off at the heater, meter or cylinder, or an empty propane tank | › |
| 12 | Flame failure (no flame). The burner lit, then the flame was lost during operation. | Gas supply interruption or low inlet gas pressure | › |
| 14 | Heat exchanger overheat. The overheat sensor (bi-metal switch) on the right side of the heat exchanger… | Scale build-up in the heat exchanger causing hot spots | › |
| 15 | Venturi control fault (SENSEI series). The venturi control device in the gas valve assembly is not operating… | Venturi control wiring loose or damaged | › |
| 16 | High outgoing water temperature - safety shutdown. Outlet water temperature exceeded 203 F (95 C) and the… | Scale blockage in the heat exchanger | › |
| 17 | Venturi blockage (SENSEI series). The venturi is blocked or obstructed. | Debris build-up in the venturi | › |
| 19 | Electrical grounding fault. If code 19 appears immediately after water flow begins with no flame in the… | Electrical short in a wiring harness, water flow control, bypass valve or other DC | › |
| 21 | Data transfer error (SENSEI series). After a PC Board replacement, the data transfer to the new board is… | Data transfer from the old PC Board not completed | › |
| 25 | Condensate pump error or drain clogged (accessory pump). Code 25 appears when the condensate safety switch… | Accessory condensate pump not running or not powered | › |
| 32 | Outgoing water temperature thermistor fault. The outlet temperature sensor signal is faulty. | Thermistor wiring loose, broken or damaged | › |
| 33 | Heat exchanger thermistor fault. The heat exchanger outlet temperature sensor signal is faulty. | Thermistor wiring loose, broken or damaged | › |
| 38 | Exhaust gas temperature sensor fault. The exhaust temperature sensor signal is faulty. | Sensor wiring loose, broken or damaged at the sensor or PC Board | › |
| 41 | Freeze protection sensor fault. The outside air / freeze protection thermistor is open, unplugged, cut or… | Sensor wiring loose, broken or damaged | › |
| 51 | Inlet water temperature thermistor fault. The inlet temperature sensor signal is faulty. If the thermistor is… | Sensor wiring loose, broken or damaged | › |
| 52 | Gas valve fault. On SENSEI models the gas valve solenoid circuit tested faulty; on non-SENSEI models code 52… | Flame rod or its wiring damaged (SENSEI checks this first) | › |
| 54 | High exhaust gas temperature. If exhaust temperature exceeds 163 F the heater first reduces its firing rate… | Scale build-up in the heat exchanger causing hot spots | › |
| 55 | 55 is the numeric display of the SS "Service Soon" alert - Rinnai's own manuals head the section "Code SS… | Service interval set at installation has elapsed | › |
| 61 | Combustion fan motor fault. The combustion fan is not operating correctly. | Fan wiring harness loose, broken or damaged | › |
| 63 | Recirculation low flow. Recirculation flow is too low - on SENSEI the flow must exceed 0.4 GPM, and the code… | Air in the recirculation line | › |
| 65 | Water flow control device fault. The water flow servo valve failed to close during the bath fill function -… | Water flow servo wiring loose or damaged | › |
| 70 | PC Board fault. The control board failed its self-check or its parameters/connections are wrong. | Parameters not properly set after board work | › |
| 71 | Gas solenoid valve circuit fault. On SENSEI models the gas solenoid circuit tested faulty; on non-SENSEI… | PC Board DIP switch left ON (it de-energises the main gas solenoid) | › |
| 72 | Flame rod fault. The flame sensing device is not producing a valid flame signal - it must maintain at least 1… | Flame rod wiring broken or damaged | › |
| FF | Maintenance has been performed. FF is a placeholder in the diagnostic code history indicating a service… | A service provider entered FF after completing maintenance (entered by pressing Up | › |
| LC | Scale build-up in the heat exchanger. LC (shown as LC0-LC9 as temporary resets accumulate, and as '00' in… | Hard water scale build-up inside the heat exchanger | › |
| LC0 | Scale build-up in the heat exchanger (the numbered form of the LC alert). LC0 is the starting state of the LC… | Hard water scale build-up inside the heat exchanger | › |
| LC1 | Scale build-up in the heat exchanger (the numbered form of the LC alert). The display has advanced to LC1 as… | Hard water scale build-up inside the heat exchanger | › |
| LC2 | Scale build-up in the heat exchanger (the numbered form of the LC alert). The display has advanced to LC2 as… | Hard water scale build-up inside the heat exchanger | › |
| LC3 | Scale build-up in the heat exchanger (the numbered form of the LC alert). The display has advanced to LC3 as… | Hard water scale build-up inside the heat exchanger | › |
| LC4 | Scale build-up in the heat exchanger (the numbered form of the LC alert). The display has advanced to LC4 as… | Hard water scale build-up inside the heat exchanger | › |
| LC5 | Scale build-up in the heat exchanger (the numbered form of the LC alert). The display has advanced to LC5 as… | Hard water scale build-up inside the heat exchanger | › |
| LC6 | Scale build-up in the heat exchanger (the numbered form of the LC alert). The display has advanced to LC6 as… | Hard water scale build-up inside the heat exchanger | › |
| LC7 | Scale build-up in the heat exchanger (the numbered form of the LC alert). The display has advanced to LC7 as… | Hard water scale build-up inside the heat exchanger | › |
| LC8 | Scale build-up in the heat exchanger (the numbered form of the LC alert). The display has advanced to LC8 as… | Hard water scale build-up inside the heat exchanger | › |
| LC9 | Scale build-up in the heat exchanger (the numbered form of the LC alert). The display has advanced to LC9 as… | Hard water scale build-up inside the heat exchanger | › |
| SE | Cascade diagnostic display (SENSEI commercial / CX series). With cascade connections, the primary water… | A secondary cascaded water heater is displaying an actual error code | › |
| SS | Service Soon alert. SS is a time-based service indicator set during installation (Parameter 03: not active… | Service interval set at installation has elapsed | › |
| Won't Turn On | A unit that does not attempt to start at all gets exactly two owner checks: check the power is on at the… | No power at the unit: breaker, outlet or the unit's power switch — every controller | › |
Non-SENSEI Series
| Code | What it means | Check first | |
|---|---|---|---|
| 02 | No burner operation during freeze protection. During a freeze-protection cycle the burner did not operate… | Gas valves closed or gas pressure not reaching the heater | › |
| 31 | Burner thermocouple fault (non-SENSEI series). The burner thermocouple's millivolt reading is outside the… | Over-firing (reading above 30 mV) from wrong manifold pressures or a blocked heat | › |
| 34 | Combustion air temperature thermistor fault (non-SENSEI series). The combustion air sensor in the fan motor… | Thermistor wiring loose, broken or damaged | › |
| 57 | Burner overheat bi-metal switch open (non-SENSEI series). One of the two bi-metal switches on the rear of the… | Burner overheating from wrong gas type or conversion | › |
| 58 | Secondary heat exchanger sensor open (non-SENSEI series). One of the two bi-metal switches on the rear of the… | Scale build-up in the secondary heat exchanger | › |
| 73 | Burner thermocouple fault (non-SENSEI series). The burner sensor circuit is faulty. | Thermocouple wiring loose, broken or damaged | › |
| 79 | Water leakage detected (non-SENSEI series). The leak detector found water inside the unit. | Heat exchanger or internal piping leaking | › |
RH180
| Code | What it means | Check first | |
|---|---|---|---|
| 07 | Circulation flow rate has dropped below 2.1 GPM (RH180 hybrid tank-tankless only - this code does not appear… | Water filter blocked or dirty, restricting circulation (the manual's named cause for a | › |
| 13 | Combustion fault (RH180 hybrid tank-tankless only). The RH180 manual does not give 13 a separate remedy list… | Combustion air screen clogged with dust or lint | › |
| 30 | FV (flammable vapor) sensor fault (RH180 hybrid tank-tankless only): the control cannot trust the… | FV sensor wiring damaged or a connector loose | › |
| 35 | Tank temperature sensor fault (RH180 hybrid tank-tankless only - the RH180's storage tank is what this sensor… | Tank temperature sensor wiring damaged or a connector loose | › |
| FE | Flammable vapors detected (RH180 hybrid tank-tankless only). The RH180's flammable-vapor sensor has detected… | Flammable vapors present near the unit - spilled or stored gasoline, solvents, paints | › |
SENSEI RX/CX Series
| Code | What it means | Check first | |
|---|---|---|---|
| 18 | Gas valve adjustment limit (SENSEI RX/CX series). The Smart-Sense gas valve reached its gas-rich or gas-lean… | Supplied gas is not correct | › |
| 22 | Gas valve adjustment fault (SENSEI RX/CX series). The gas valve reed switch position or the entered gas valve… | Reed switch on the front of the gas valve not properly located | › |
| 34 | Lime detecting thermistor fault (SENSEI RX/CX series). The lime-detection thermistor on the hot water pipe… | Lime thermistor wiring loose, broken or damaged | › |
| 66 | Bypass flow servo fault (SENSEI RX/CX series). The bypass flow control device is not operating correctly. | Wet bypass servo harness or connector | › |
Looking for a part?
Once you know the part you need, browse Rinnai Water heater replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.