Rinnai Water heater Error Codes

Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 58 codes covered.

Finding your model number: it is on the unit's rating plate.

Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.

All models

CodeWhat it meansCheck first
00Scale build-up in the heat exchanger - the same alert as LC in its maintenance-history form: Rinnai's…Hard water scale build-up inside the heat exchanger›
03Power interruption during bath fill. Power was lost while a bath fill (MC-100V/BC-100V controller) was…Power outage or interruption during a bath fill cycle›
05Bypass flow control device fault. The bypass flow control that blends cold water to temper the outlet is not…Bypass flow control device failed›
10Air supply or exhaust blockage, or the condensate trap is full. The unit cannot move combustion air/exhaust…Blocked condensate drain line or full condensate trap (condensing models)›
11No ignition. The heater tried to light and did not ignite (heater not turning on).Gas turned off at the heater, meter or cylinder, or an empty propane tank›
12Flame failure (no flame). The burner lit, then the flame was lost during operation.Gas supply interruption or low inlet gas pressure›
14Heat exchanger overheat. The overheat sensor (bi-metal switch) on the right side of the heat exchanger…Scale build-up in the heat exchanger causing hot spots›
15Venturi control fault (SENSEI series). The venturi control device in the gas valve assembly is not operating…Venturi control wiring loose or damaged›
16High outgoing water temperature - safety shutdown. Outlet water temperature exceeded 203 F (95 C) and the…Scale blockage in the heat exchanger›
17Venturi blockage (SENSEI series). The venturi is blocked or obstructed.Debris build-up in the venturi›
19Electrical grounding fault. If code 19 appears immediately after water flow begins with no flame in the…Electrical short in a wiring harness, water flow control, bypass valve or other DC›
21Data transfer error (SENSEI series). After a PC Board replacement, the data transfer to the new board is…Data transfer from the old PC Board not completed›
25Condensate pump error or drain clogged (accessory pump). Code 25 appears when the condensate safety switch…Accessory condensate pump not running or not powered›
32Outgoing water temperature thermistor fault. The outlet temperature sensor signal is faulty.Thermistor wiring loose, broken or damaged›
33Heat exchanger thermistor fault. The heat exchanger outlet temperature sensor signal is faulty.Thermistor wiring loose, broken or damaged›
38Exhaust gas temperature sensor fault. The exhaust temperature sensor signal is faulty.Sensor wiring loose, broken or damaged at the sensor or PC Board›
41Freeze protection sensor fault. The outside air / freeze protection thermistor is open, unplugged, cut or…Sensor wiring loose, broken or damaged›
51Inlet water temperature thermistor fault. The inlet temperature sensor signal is faulty. If the thermistor is…Sensor wiring loose, broken or damaged›
52Gas valve fault. On SENSEI models the gas valve solenoid circuit tested faulty; on non-SENSEI models code 52…Flame rod or its wiring damaged (SENSEI checks this first)›
54High exhaust gas temperature. If exhaust temperature exceeds 163 F the heater first reduces its firing rate…Scale build-up in the heat exchanger causing hot spots›
5555 is the numeric display of the SS "Service Soon" alert - Rinnai's own manuals head the section "Code SS…Service interval set at installation has elapsed›
61Combustion fan motor fault. The combustion fan is not operating correctly.Fan wiring harness loose, broken or damaged›
63Recirculation low flow. Recirculation flow is too low - on SENSEI the flow must exceed 0.4 GPM, and the code…Air in the recirculation line›
65Water flow control device fault. The water flow servo valve failed to close during the bath fill function -…Water flow servo wiring loose or damaged›
70PC Board fault. The control board failed its self-check or its parameters/connections are wrong.Parameters not properly set after board work›
71Gas solenoid valve circuit fault. On SENSEI models the gas solenoid circuit tested faulty; on non-SENSEI…PC Board DIP switch left ON (it de-energises the main gas solenoid)›
72Flame rod fault. The flame sensing device is not producing a valid flame signal - it must maintain at least 1…Flame rod wiring broken or damaged›
FFMaintenance has been performed. FF is a placeholder in the diagnostic code history indicating a service…A service provider entered FF after completing maintenance (entered by pressing Up›
LCScale build-up in the heat exchanger. LC (shown as LC0-LC9 as temporary resets accumulate, and as '00' in…Hard water scale build-up inside the heat exchanger›
LC0Scale build-up in the heat exchanger (the numbered form of the LC alert). LC0 is the starting state of the LC…Hard water scale build-up inside the heat exchanger›
LC1Scale build-up in the heat exchanger (the numbered form of the LC alert). The display has advanced to LC1 as…Hard water scale build-up inside the heat exchanger›
LC2Scale build-up in the heat exchanger (the numbered form of the LC alert). The display has advanced to LC2 as…Hard water scale build-up inside the heat exchanger›
LC3Scale build-up in the heat exchanger (the numbered form of the LC alert). The display has advanced to LC3 as…Hard water scale build-up inside the heat exchanger›
LC4Scale build-up in the heat exchanger (the numbered form of the LC alert). The display has advanced to LC4 as…Hard water scale build-up inside the heat exchanger›
LC5Scale build-up in the heat exchanger (the numbered form of the LC alert). The display has advanced to LC5 as…Hard water scale build-up inside the heat exchanger›
LC6Scale build-up in the heat exchanger (the numbered form of the LC alert). The display has advanced to LC6 as…Hard water scale build-up inside the heat exchanger›
LC7Scale build-up in the heat exchanger (the numbered form of the LC alert). The display has advanced to LC7 as…Hard water scale build-up inside the heat exchanger›
LC8Scale build-up in the heat exchanger (the numbered form of the LC alert). The display has advanced to LC8 as…Hard water scale build-up inside the heat exchanger›
LC9Scale build-up in the heat exchanger (the numbered form of the LC alert). The display has advanced to LC9 as…Hard water scale build-up inside the heat exchanger›
SECascade diagnostic display (SENSEI commercial / CX series). With cascade connections, the primary water…A secondary cascaded water heater is displaying an actual error code›
SSService Soon alert. SS is a time-based service indicator set during installation (Parameter 03: not active…Service interval set at installation has elapsed›
Won't Turn OnA unit that does not attempt to start at all gets exactly two owner checks: check the power is on at the…No power at the unit: breaker, outlet or the unit's power switch — every controller›

Non-SENSEI Series

CodeWhat it meansCheck first
02No burner operation during freeze protection. During a freeze-protection cycle the burner did not operate…Gas valves closed or gas pressure not reaching the heater›
31Burner thermocouple fault (non-SENSEI series). The burner thermocouple's millivolt reading is outside the…Over-firing (reading above 30 mV) from wrong manifold pressures or a blocked heat›
34Combustion air temperature thermistor fault (non-SENSEI series). The combustion air sensor in the fan motor…Thermistor wiring loose, broken or damaged›
57Burner overheat bi-metal switch open (non-SENSEI series). One of the two bi-metal switches on the rear of the…Burner overheating from wrong gas type or conversion›
58Secondary heat exchanger sensor open (non-SENSEI series). One of the two bi-metal switches on the rear of the…Scale build-up in the secondary heat exchanger›
73Burner thermocouple fault (non-SENSEI series). The burner sensor circuit is faulty.Thermocouple wiring loose, broken or damaged›
79Water leakage detected (non-SENSEI series). The leak detector found water inside the unit.Heat exchanger or internal piping leaking›

RH180

CodeWhat it meansCheck first
07Circulation flow rate has dropped below 2.1 GPM (RH180 hybrid tank-tankless only - this code does not appear…Water filter blocked or dirty, restricting circulation (the manual's named cause for a›
13Combustion fault (RH180 hybrid tank-tankless only). The RH180 manual does not give 13 a separate remedy list…Combustion air screen clogged with dust or lint›
30FV (flammable vapor) sensor fault (RH180 hybrid tank-tankless only): the control cannot trust the…FV sensor wiring damaged or a connector loose›
35Tank temperature sensor fault (RH180 hybrid tank-tankless only - the RH180's storage tank is what this sensor…Tank temperature sensor wiring damaged or a connector loose›
FEFlammable vapors detected (RH180 hybrid tank-tankless only). The RH180's flammable-vapor sensor has detected…Flammable vapors present near the unit - spilled or stored gasoline, solvents, paints›

SENSEI RX/CX Series

CodeWhat it meansCheck first
18Gas valve adjustment limit (SENSEI RX/CX series). The Smart-Sense gas valve reached its gas-rich or gas-lean…Supplied gas is not correct›
22Gas valve adjustment fault (SENSEI RX/CX series). The gas valve reed switch position or the entered gas valve…Reed switch on the front of the gas valve not properly located›
34Lime detecting thermistor fault (SENSEI RX/CX series). The lime-detection thermistor on the hot water pipe…Lime thermistor wiring loose, broken or damaged›
66Bypass flow servo fault (SENSEI RX/CX series). The bypass flow control device is not operating correctly.Wet bypass servo harness or connector›
Looking for a part?

Once you know the part you need, browse Rinnai Water heater replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.