Rinnai Water heater 25 Error Code

What the 25 code means

Condensate pump error or drain clogged (accessory pump). Code 25 appears when the condensate safety switch contacts close - condensate is backing up and tripping the float switch, or the accessory condensate pump has stopped working.

Likely causes

  1. Accessory condensate pump not running or not powered
  2. Clogged or frozen condensate drain line
  3. Blocked condensate trap
  4. Pump wiring fault back to the PC Board

How to fix it — step by step

  1. Find the condensate pump first: it is an external accessory - a small reservoir box sitting on the floor beside or below the unit, with drain tubing running into it from the condensate outlet at the bottom of the heater cabinet. Confirm power is supplied to the pump and check it runs when its reservoir fills; a pump that stays silent with power supplied and a full reservoir has failed. → Shop the condensate pump (accessory) at Amazon
  2. Follow the drain line from the condensate outlet at the bottom of the unit: ensure it is not clogged or frozen and has an air gap at the discharge end. A blocked or frozen line backs condensate up until the safety switch trips, which is what code 25 is reporting.
  3. Inspect the condensate trap for restrictions and clear it - on these units the trap is inside the bottom of the cabinet, reached with the front panel off (power disconnected first).
  4. Check all wiring for loose, damaged or broken connections from the pump and trap back to the PC Board.
  5. Replace the condensate pump if it does not operate with power supplied, then run a hot water draw and confirm condensate discharges freely and 25 does not return.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 25 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.