What the 11 code means
No ignition. The heater tried to light and did not ignite (heater not turning on).
Likely causes
- Gas turned off at the heater, meter or cylinder, or an empty propane tank
- Air in the gas lines
- Wrong gas type, inlet pressure or gas type parameter/DIP setting
- Igniter not sparking or a loose/fouled flame rod
How to fix it — step by step
- Check the gas is turned on at the water heater, meter or cylinder, and if the system is propane, that there is gas in the tank - no gas supply produces exactly this code with nothing wrong inside the heater.
- Verify air was purged from the gas lines and inlet gas pressure matches the rating plate at high fire.
- Verify the gas type is correct (Parameter 10 on SENSEI: A = natural gas, B = propane).
- Have a technician test the ignition parts where they live: the igniter (spark electrode) and flame rod are mounted in the burner assembly at the top of the heat exchanger, reached by removing the front panel (screws). The technician tests the igniter for spark and confirms the ceramic sparker electrode and flame rod are tight in their bracket - cleaning carbon or white build-up off both and refitting with a new electrode/flame rod gasket if loose. A strong spark with gas present rules the igniter out and points back to gas delivery; no spark points to the igniter or the board output driving it. → Shop the electrode/flame rod gasket at Amazon → Shop the igniter (spark electrode) at Amazon
- Measure the flame signal the way Rinnai specifies: meter in series with the flame rod on the micro-amp scale - 1 uA or greater is a proper flame circuit (a rod-to-ground check on the running unit should read 5-150 V AC). Below range with a clean, correctly gapped rod, work the ground and wiring before condemning parts → Shop the flame rod at Amazon
- Put a number on the spark circuit before replacing it: Rinnai's electrical diagnostics rate the spark electrode at 34-40 kΩ resistance on an 11-13 V DC drive - an open or shorted reading condemns the electrode circuit, not the board
- If ignition still fails, the technician works through venting, altitude setting and wiring, ending at the gas valve or PC Board if faulty.
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 11 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the Igniter (spark electrode).
Shop the Igniter (spark electrode) at Amazon
Also tied to this fault: Flame rod - Shop at Amazon; Electrode/flame rod gasket - Shop at Amazon; Gas valve assembly - Shop at Amazon; PC Board - Shop at Amazon
Parts that commonly fix the 11 code
- Igniter (spark electrode)Shop at Amazon
- Flame rod$10–$60Shop at Amazon
- Electrode/flame rod gasket$10–$60Shop at Amazon
- Gas valve assembly$115–$500Shop at Amazon
- PC Board$100–$300Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
Before you buy: check the flame rod first
Test: Meter in series with the flame rod on the micro-amp scale while the unit fires (Rinnai Electrical Diagnostics); or one lead on the rod and the other to ground with the unit running, meter on AC volts.
A good one reads: 1 uA or greater is a proper flame circuit; the rod-to-ground method should read 5-150 V AC. Below range with a clean rod: check carbon build-up, wiring and ground before replacing parts.
Test values from images.tradeservice.com documentation - confirm against your model's own tech sheet.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.