Rinnai Water heater 41 Error Code
What the 41 code means
Freeze protection sensor fault. The outside air / freeze protection thermistor is open, unplugged, cut or shorted. On most models the heater keeps operating and flashes 41 alternating with the set temperature, because this sensor only activates freeze protection.
Likely causes
- Sensor wiring loose, broken or damaged
- Sensor covered with insulation instead of open to outside air
- Failed freeze protection thermistor
How to fix it — step by step
- Check the sensor wiring harness for loose, broken or damaged connections back to the PC Board
- Ensure the sensor is open to outside air and not covered with insulation
- Test resistance on the 20K ohm scale (11.4-14K ohms at 59 F, 6.4-7.8K at 86 F, 2.2-2.7K at 140 F) - the code disappears once the cause is cleared
- Replace the freeze protection sensor if its readings are out of range
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 41 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Freeze protection thermistor (outside temperature sensor).
Shop the Freeze protection thermistor (outside temperature sensor) at Amazon
Parts that commonly fix the 41 code
- Freeze protection thermistor (outside temperature sensor)$25–$80Shop at Amazon
- Tools for this job, if you need them$15–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
Before you buy: check the freeze protection thermistor (outside temperature sensor) first
Test: Power disconnected and the sensor isolated: insert the meter leads into each end of the thermistor plug, meter on the 20K scale (Rinnai Electrical Diagnostics).
A good one reads: 11.4-14 kΩ at 59 °F; 6.4-7.8 kΩ at 86 °F; 3.6-4.5 kΩ at 113 °F; 2.2-2.7 kΩ at 140 °F. Warming the bulb must lower the reading and icing it must raise it; a fixed or open reading condemns the sensor.
Test values from images.tradeservice.com documentation - confirm against your model's own tech sheet.