Rinnai Water heater Non-SENSEI Series 34 Error Code

What the 34 code means

Combustion air temperature thermistor fault (non-SENSEI series). The combustion air sensor in the fan motor housing signal is faulty.

Likely causes

  1. Thermistor wiring loose, broken or damaged
  2. Failed combustion air temperature thermistor

How to fix it — step by step

  1. Check the thermistor wiring harness for loose, broken or damaged connections back to the PC Board
  2. Remove the thermistor from the fan motor housing and test resistance on the 20K ohm scale (11.4-14K ohms at 59 F, falling as the bulb warms)
  3. Verify the correct gas type, clearances and DIP switches while the unit is open
  4. If code 34 still appears, replace the combustion air temperature thermistor
  5. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 34 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 34 code

Parts run $25–$80Typical pro repair $228–$1,017Fixing it yourself typically saves $148–$992
  • Combustion air temperature thermistor$25–$80Shop at Amazon
  • Tools for this job, if you need them$15–$65

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

Before you buy: check the combustion air temperature thermistor first

Test: Power disconnected and the sensor isolated: insert the meter leads into each end of the thermistor plug, meter on the 20K scale (Rinnai Electrical Diagnostics).

A good one reads: 11.4-14 kΩ at 59 °F; 6.4-7.8 kΩ at 86 °F; 3.6-4.5 kΩ at 113 °F; 2.2-2.7 kΩ at 140 °F. Warming the bulb must lower the reading and icing it must raise it; a fixed or open reading condemns the sensor.

Test values from images.tradeservice.com documentation - confirm against your model's own tech sheet.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manufacturer documentation

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Rinnai Water heater Non-SENSEI Series error codes

See all Rinnai Non-SENSEI Series codes & guides →