Rinnai Water heater RH180 30 Error Code

What the 30 code means

FV (flammable vapor) sensor fault (RH180 hybrid tank-tankless only): the control cannot trust the flammable-vapor sensor's reading. This is the sensor circuit reporting a fault - it is code FE, not this one, that means vapors have actually been detected. The manual's remedies are electrical: the sensor's wiring and the sensor itself, proven with a meter.

Likely causes

  1. FV sensor wiring damaged or a connector loose
  2. FV sensor failed - its resistance out of the manual's specified range

How to fix it — step by step

  1. Check the FV sensor's wiring first (the manual's first remedy): with the unit's power off, trace the sensor harness for damaged insulation, pinched sections or a backed-out connector, and reseat the connector.
  2. Measure the resistance of the sensor with a meter and compare it with the manual's electrical-diagnostics values for the FV sensor: a reading in spec with sound wiring clears the sensor; a reading out of spec condemns it.
  3. Replace an out-of-spec FV sensor, restore power, and verify 30 stays clear through a full heating cycle.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 30 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manufacturer documentation

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Rinnai Water heater RH180 error codes

See all Rinnai RH180 codes & guides →