Rinnai Water heater Non-SENSEI Series 31 Error Code

What the 31 code means

Burner thermocouple fault (non-SENSEI series). The burner thermocouple's millivolt reading is outside the normal 20-27 mV combustion range - the heater sets code 31 above 30 mV or below 8 mV.

Likely causes

  1. Over-firing (reading above 30 mV) from wrong manifold pressures or a blocked heat exchanger
  2. Low gas pressure or low-Btu gas (reading below 8 mV)
  3. Failed burner thermocouple

How to fix it — step by step

  1. Check low/high fire manifold pressures against the tech sheet inside the front cover and set them for your altitude
  2. Verify all DIP switches are in the proper position for altitude
  3. Measure the thermocouple millivolt reading during combustion; if above 30 mV check for blockage between the heat exchanger fins and clean or replace the exchanger, if below 8 mV verify forced low fire gas pressure → Shop the heat exchanger at Amazon
  4. Replace the burner thermocouple if pressures are correct and the reading stays out of range → Shop the burner thermocouple at Amazon
  5. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 31 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 31 code

Parts run $300–$900Typical pro repair $228–$1,017

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manufacturer documentation

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Rinnai Water heater Non-SENSEI Series error codes

See all Rinnai Non-SENSEI Series codes & guides →