Rinnai Water heater 61 Error Code

What the 61 code means

Combustion fan motor fault. The combustion fan is not operating correctly.

Likely causes

  1. Fan wiring harness loose, broken or damaged
  2. Debris in the fan housing stopping the wheel
  3. Stuck check valve behind the fan motor (SENSEI)
  4. Fan motor windings open

How to fix it — step by step

  1. Turn off power and gas before servicing the fan - never plug or unplug the motor with power supplied
  2. Check the wiring harness from the fan motor back to the PC Board
  3. Remove the fan motor and inspect the blower wheel - it must turn freely - and clear any debris from the fan housing; on SENSEI models ensure the check valve behind the fan is not stuck closed
  4. Measure the fan motor winding resistance against the tech sheet - replace the motor if windings are open
  5. If windings and voltage are in specification and the wheel turns freely, replace the PC Board → Shop the pc board at Amazon
  6. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 61 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 61 code

Parts run $100–$300Typical pro repair $228–$1,017

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.