Rinnai Water heater 05 Error Code

What the 05 code means

Bypass flow control device fault. The bypass flow control that blends cold water to temper the outlet is not operating correctly.

Likely causes

  1. Bypass flow control device failed
  2. Device wiring or resistance out of specification

How to fix it — step by step

  1. Access (Rinnai water flow control instructions): turn off gas, water and 120 V power, drain the appliance, remove the four screws securing the front panel and remove the front panel; on indoor models also remove the temperature controller and its bracket. The water flow servo assembly and the bypass servo assembly sit together at the bottom of the cabinet on the water inlet. The bypass flow control device is the bypass servo assembly attached to that water flow servo assembly — its harness is the white/red/yellow/orange/brown connector set in the Rinnai instructions.
  2. For SENSEI models, measure the bypass flow control resistance at the PC Board connector (44-52 ohms on each winding pair per the tech sheet): in-range windings with correct board drive rule the device in as good; out-of-range resistance condemns the bypass device itself. → Shop the bypass flow control device (bypass valve) at Amazon
  3. For non-SENSEI models, turn the power off and back on, then run a hot water fixture — if code 05 reappears, replace the bypass valve.
  4. Replace the bypass flow control device: disconnect the harnesses, remove the two screws and retention clips at the bypass valve and the two copper tubes, separate the bypass servo assembly from the water flow servo assembly (two screws), fit the new device with the new O-ring between the assemblies, refit the screws/clips/tubes and harnesses, restore the water inlet screws, controller and front panel, then refill and prove temperature tempering on a draw.
  5. Tell the technician: code 05, the winding resistance readings (SENSEI) or the power-cycle result (non-SENSEI). What this job involves: draining the unit and opening the bottom waterway assembly inside the cabinet.
  6. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 05 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 05 code

  • Bypass flow control device (bypass valve)Shop at Amazon
  • Tools for this job, if you need them$10–$65

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.