Rinnai Water heater 63 Error Code

What the 63 code means

Recirculation low flow. Recirculation flow is too low - on SENSEI the flow must exceed 0.4 GPM, and the code also sets if recirculation is programmed on with no pump connected.

Likely causes

  1. Air in the recirculation line
  2. Clogged inlet or bypass filters
  3. Recirculation pump not getting 120 VAC or not running
  4. Wrong recirculation parameter/DIP or mode setting
  5. Leak or restriction in the home recirculation loop

How to fix it — step by step

  1. Clear the inlet and bypass filters of debris, reinstall and bleed the plumbing system of all air; ensure cold inlet and hot outlet valves are open and purge air at the bleeder valve below the heater
  2. Ensure the recirculation pump is getting 120 VAC at its harness and the parameter for Economy/Comfort and recirculation mode (Parameter 04) is correctly set - set Parameter 04 to A (no recirculation) if no pump is connected
  3. Check the dedicated return line length and check valves, and test the home loop for leaks (a leak lets the pump draw air in)
  4. If code 63 persists with a clean, bled, leak-free loop, have a technician test the circulation pump
  5. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 63 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 63 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.