Rinnai Water heater 51 Error Code

What the 51 code means

Inlet water temperature thermistor fault. The inlet temperature sensor signal is faulty. If the thermistor is open or disconnected the heater keeps operating and flashes 51 alternating with the set point.

Likely causes

  1. Sensor wiring loose, broken or damaged
  2. Scale build-up on the sensor
  3. Failed inlet water temperature thermistor

How to fix it — step by step

  1. Check the sensor wiring harness for loose, broken or damaged connections back to the PC Board
  2. Turn off the water supply, drain the system, remove the sensor and clean any scale off it
  3. Test resistance on the 20K ohm scale (11.4-14K ohms at 59 F, falling as the bulb warms); reinstall with its O-ring intact and a little grease, refill and check for leaks
  4. Re-fire the heater - if code 51 still appears, replace the inlet water temperature thermistor → Shop the inlet water temperature thermistor at Amazon
  5. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 51 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 51 code

Parts run $25–$80Typical pro repair $228–$1,017Fixing it yourself typically saves $148–$992
  • Inlet water temperature thermistor$25–$80Shop at Amazon
  • Tools for this job, if you need them$15–$65

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

Before you buy: check the inlet water temperature thermistor first

Test: Power disconnected and the sensor isolated: insert the meter leads into each end of the thermistor plug, meter on the 20K scale (Rinnai Electrical Diagnostics).

A good one reads: 11.4-14 kΩ at 59 °F; 6.4-7.8 kΩ at 86 °F; 3.6-4.5 kΩ at 113 °F; 2.2-2.7 kΩ at 140 °F. Warming the bulb must lower the reading and icing it must raise it; a fixed or open reading condemns the sensor.

Test values from images.tradeservice.com documentation - confirm against your model's own tech sheet.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manufacturer documentation

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Rinnai Water heater error codes

See all Rinnai water heater codes & guides →