What the SS code means

Service Soon alert. SS is a time-based service indicator set during installation (Parameter 03: not active, 0.5 year, 1 year or 2 years) - it is time for service and the heat exchanger should be flushed to prevent damage.

Likely causes

  1. Service interval set at installation has elapsed
  2. Scale building up in the heat exchanger from hard water

How to fix it — step by step

  1. Find the isolation (service) valves on the plumbing directly below the unit - hot (red handle) and cold (blue handle), each with a capped service port. Flush the heat exchanger: isolate the unit with those valves, connect a circulation pump to push descaling solution in through the cold service port and a return hose from the hot service port to a bucket, and circulate (about an hour). If the unit has no isolation valves fitted, they have to be added before flushing is possible.
  2. Treat hard water to prevent scale build-up or damage to the heat exchanger - SS is time-based, but the service it is calling for is the flush.
  3. Reset SS only after servicing: on SENSEI push the On/Off button on the temperature controller five times in five seconds (on RX/CX, push and hold the 'A' button until SS disappears) - resetting without flushing leaves the exchanger unprotected.
  4. Verify the fix: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - SS should stay clear through the whole draw. If it comes back, the fault is still present: recheck the step above whose result was borderline, and treat the part that step points to as the one to replace

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the SS code

Parts run $300–$900Typical pro repair $228–$1,017
  • Heat exchanger descaling flush kit (circulation pump and descaling solution)$300–$900Shop at Amazon

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.