Rinnai Water heater Non-SENSEI Series 57 Error Code

What the 57 code means

Burner overheat bi-metal switch open (non-SENSEI series). One of the two bi-metal switches on the rear of the burner assembly opened. Code 57 shows whether or not the heater is operating, and resets only after the cause is corrected with a hard power reset.

Likely causes

  1. Burner overheating from wrong gas type or conversion
  2. Manifold pressures not set for altitude
  3. Failed burner overheat bi-metal switch
  4. Switch wiring loose or damaged

How to fix it — step by step

  1. Check the bi-metal switch wiring harness for loose, broken or damaged connections back to the PC Board
  2. Verify the heater is connected to the proper gas type and any conversion was done to the manufacturer's procedure with correct pressures and DIP switches
  3. Verify low/high fire manifold pressures are set properly for your elevation
  4. Correct the cause, then hard-reset by turning power off and back on; replace the bi-metal switch sensor if it tests open with no overheat cause
  5. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 57 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 57 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manufacturer documentation

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Rinnai Water heater Non-SENSEI Series error codes

See all Rinnai Non-SENSEI Series codes & guides →