Rinnai Water heater 17 Error Code
What the 17 code means
Venturi blockage (SENSEI series). The venturi is blocked or obstructed.
Likely causes
- Debris build-up in the venturi
- Blocked condensate drain line
- Obstruction in the intake, exhaust chamber or vent termination
How to fix it — step by step
- Verify the condensate drain line is properly draining
- Inspect the entire vent system - intake air, exhaust chamber and vent termination - for obstructions
- Remove the gas valve and venturi assembly from the fan motor and inspect the venturi for debris, clean it out and reinstall
- Run the reset procedure on the PC Board buttons (step through B button displays to 'E', then hold A and B for 10 seconds until 'ECL' shows) to return the heater to normal operation
- Verify the fix: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 17 should stay clear through the whole draw. If it comes back, the fault is still present: recheck the step above whose result was borderline, and treat the part that step points to as the one to replace
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Gas valve and venturi assembly.
Parts that commonly fix the 17 code
- Gas valve and venturi assembly$115–$500Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.