Rinnai Water heater Non-SENSEI Series 79 Error Code
What the 79 code means
Water leakage detected (non-SENSEI series). The leak detector found water inside the unit.
Likely causes
- Heat exchanger or internal piping leaking
- Water pooled in the bottom pan from condensation or a past leak
- Failed leak sensor
How to fix it — step by step
- Check the leak detector wiring harness for loose, broken or damaged connections
- Check the heat exchanger and all piping inside the water heater for leaks and repair any leak found
- If no leak is found, wipe or blow out any water pooled in the cabinet bottom pan, dry the leak sensor and restart the heater
- If no water is found, unplug the sensor and fire the heater - if it operates with the sensor unplugged, replace the leak sensor and screw → Shop the leak sensor at Amazon
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 79 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Leak sensor.
Shop the Leak sensor at Amazon
Also tied to this fault: Heat exchanger - Shop at Amazon
Parts that commonly fix the 79 code
- Leak sensorShop at Amazon
- Heat exchanger$300–$900Shop at Amazon
- Tools for this job, if you need them$25–$200
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number