Rinnai Water heater 71 Error Code

What the 71 code means

Gas solenoid valve circuit fault. On SENSEI models the gas solenoid circuit tested faulty; on non-SENSEI models one of the SV0-SV3 gas solenoid valves is faulty.

Likely causes

  1. PC Board DIP switch left ON (it de-energises the main gas solenoid)
  2. Solenoid wiring loose, broken or damaged
  3. A gas solenoid coil open (no resistance)
  4. Mechanical obstruction inside the gas valve
  5. PC Board fault

How to fix it — step by step

  1. Ensure the single DIP switch on the PC Board is in the OFF position (SENSEI) — left ON, it de-energises the main gas solenoid and sets this code with no failed part.
  2. Where the solenoids live: the gas valve assembly with its SV0–SV4 solenoids is inside the cabinet — remove the front cover and follow the solenoid harnesses back to the PC Board; the board's connector D is where the documented measurements are made.
  3. Check the gas solenoid wiring harnesses for loose, broken or damaged connections, and on non-SENSEI models check for moisture in the plastic tube from the bottom of the combustion box to the gas valve — moisture there means replace the gas valve and then find and fix the water source, or the new valve fails the same way.
  4. Measure solenoid resistance/voltage at the PC Board connector D (black pin 27 / yellow pin 29 on SENSEI): 18–22 ohms or 11–13 VDC is the documented good reading. Any solenoid reading open (no resistance) condemns the gas valve — the solenoids are serviced with the gas valve (and burner manifold where new solenoids are fitted), not individually. → Shop the pc board at Amazon
  5. Replace the gas valve if faulty; if code 71 persists with all solenoids reading in specification and the heater circuit confirmed not grounded, replace the PC Board.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 71 code

Typical pro repair $228–$1,017

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manufacturer documentation

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Rinnai Water heater error codes