Rinnai Water heater Non-SENSEI Series 73 Error Code

What the 73 code means

Burner thermocouple fault (non-SENSEI series). The burner sensor circuit is faulty.

Likely causes

  1. Thermocouple wiring loose, broken or damaged
  2. DIP altitude settings wrong
  3. Manifold gas pressures not at factory specification for altitude
  4. Failed burner thermocouple

How to fix it — step by step

  1. Check the wiring harness at the burner thermocouple back to the PC Board for loose, broken or damaged connections
  2. Verify all DIP settings are set to the proper altitude per the tech sheet under the front panel
  3. Confirm low/high fire manifold gas pressures are set to factory specification for the installation altitude (manometer required - gas work)
  4. Replace the burner thermocouple; if the code reappears after replacement, replace the PC Board → Shop the burner thermocouple at Amazon → Shop the pc board at Amazon
  5. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 73 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 73 code

Parts run $100–$300Typical pro repair $228–$1,017

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.