Rinnai Water heater Non-SENSEI Series 58 Error Code

What the 58 code means

Secondary heat exchanger sensor open (non-SENSEI series). One of the two bi-metal switches on the rear of the secondary heat exchanger, where the air box connects, opened - this code indicates scale build-up inside the secondary heat exchanger.

Likely causes

  1. Scale build-up in the secondary heat exchanger
  2. Sensor wiring loose or damaged
  3. Failed secondary heat exchanger bi-metal switch

How to fix it — step by step

  1. Check the sensor wiring harness for loose, broken or damaged connections back to the PC Board and measure the circuit resistance (should be less than 1 ohm)
  2. Flush the heat exchanger following the flushing procedure in the owner's manual, using the isolation/service valves, a circulation pump and descaling solution, and treat hard water to prevent scale returning
  3. Correct the cause, then hard-reset by turning power off and back on - code 58 only resets after the bi-metal switch problem is corrected
  4. Verify the fix: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 58 should stay clear through the whole draw. If it comes back, the fault is still present: recheck the step above whose result was borderline, and treat the part that step points to as the one to replace

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 58 code

Parts run $300–$900Typical pro repair $228–$1,017
  • Secondary heat exchanger bi-metal switch$300–$900Shop at Amazon
  • Heat exchanger descaling flush kit (circulation pump and descaling solution)$300–$900Shop at Amazon

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manufacturer documentation

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Rinnai Water heater Non-SENSEI Series error codes

See all Rinnai Non-SENSEI Series codes & guides →