Rinnai Water heater SENSEI RX/CX Series 66 Error Code
What the 66 code means
Bypass flow servo fault (SENSEI RX/CX series). The bypass flow control device is not operating correctly.
Likely causes
- Wet bypass servo harness or connector
- Bypass flow control resistance out of range (40-60 ohms per winding pair at connector CN10)
- PC Board fault
How to fix it — step by step
- Access (Rinnai water flow control instructions): turn off gas, water and 120 V power, drain the appliance, remove the four screws securing the front panel and remove the front panel; on indoor models also remove the temperature controller and its bracket. The water flow servo assembly and the bypass servo assembly sit together at the bottom of the cabinet on the water inlet. The bypass flow control device is the bypass servo assembly attached to the water flow servo assembly at the bottom inlet.
- Verify the harness and connector are not wet — dry them and find the moisture source if they are; a wet connector alone can set this code, and refitting a dry, sound connector may be the whole repair.
- Measure the bypass flow control resistance at the PC Board connector CN10 (40-60 ohms on each pair per the tech sheet). → Shop the pc board at Amazon
- Follow the test result: if one of the resistance values is out of range, replace the PC Board; otherwise replace the bypass flow control device. That split is the pinpoint — do not replace both on a guess. → Shop the bypass flow control device at Amazon
- Replace the bypass device: disconnect the harnesses, remove the two screws and retention clips at the bypass valve and the two copper tubes, separate the bypass servo assembly from the water flow servo assembly (two screws), fit the new device with the new O-ring between assemblies, refit in reverse, restore controller and front panel, refill and prove tempering on a draw. A PC Board replacement is: power/gas off, front panel off, connectors transferred one-for-one to the new board, parameters/data set per the PCB replacement instructions, then a proof cycle.
- Tell the technician: code 66, whether the connector was wet, and the CN10 resistance readings. What this job involves: draining the unit for the servo path; board handling with power isolated for the PC Board path.
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 66 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Bypass flow control device.
Shop the Bypass flow control device at Amazon
Also tied to this fault: PC Board - Shop at Amazon
Parts that commonly fix the 66 code
- Bypass flow control deviceShop at Amazon
- PC Board$100–$300Shop at Amazon
- Tools for this job, if you need them$10–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.