What the 16 code means
High outgoing water temperature - safety shutdown. Outlet water temperature exceeded 203 F (95 C) and the heater shut down.
Likely causes
- Scale blockage in the heat exchanger
- Restricted air flow at the vent terminal or a stuck fan check valve
- Foreign material in the combustion chamber or exhaust
- Wrong gas type setting
How to fix it — step by step
- Check for restrictions in air flow around the vent terminal
- Check the fan operates and the check valve behind the fan motor is not stuck restricting air flow
- Check for foreign materials in the combustion chamber and exhaust piping and for blockage in the heat exchanger - flush the heat exchanger if scaled
- Verify the gas type matches the rating plate (Parameter 10 on SENSEI: A = natural gas, B = propane)
- If code 16 persists, replace the gas valve assembly, then the fan motor assembly if faulty → Shop the gas valve assembly at Amazon
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 16 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Gas valve assembly.
Shop the Gas valve assembly at Amazon
Also tied to this fault: Combustion fan motor - Shop at Amazon; Heat exchanger descaling flush kit (circulation pump and descaling solution) - Shop at Amazon
Parts that commonly fix the 16 code
- Gas valve assembly$115–$500Shop at Amazon
- Combustion fan motor$100–$300Shop at Amazon
- Heat exchanger descaling flush kit (circulation pump and descaling solution)$300–$900Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.