What the 72 code means
Flame rod fault. The flame sensing device is not producing a valid flame signal - it must maintain at least 1 micro amp with flame present.
Likely causes
- Flame rod wiring broken or damaged
- Carbon build-up on the flame rod
- Flame rod not touching the flame
- Heat exchanger leaking onto the flame circuit
- PC Board fault
How to fix it — step by step
- Check the wiring harnesses to the flame rods for broken or damaged connections back to the PC Board
- Ensure the flame rod is touching the flame when the heater fires
- Remove the flame rod and check for carbon build-up - clean it, and replace the flame rod and its gasket if necessary → Shop the flame rod gasket at Amazon → Shop the flame rod at Amazon
- Measure the micro amp output from the flame rod (minimum 1 micro amp)
- Verify the heat exchanger is not leaking and replace it if it is; if the rod and circuit test good, replace the PC Board (transferring data to the new board on SENSEI models) → Shop the heat exchanger at Amazon → Shop the pc board at Amazon
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Flame rod.
Also tied to this fault: Flame rod gasket - Shop at Amazon; PC Board - Shop at Amazon; Heat exchanger - Shop at Amazon
Parts that commonly fix the 72 code
- Flame rod$10–$60Shop at Amazon
- Flame rod gasket$10–$60Shop at Amazon
- PC Board$100–$300Shop at Amazon
- Heat exchanger$300–$900Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
Before you buy: check the flame rod first
Test: Meter in series with the flame rod on the micro-amp scale while the unit fires (Rinnai Electrical Diagnostics); or one lead on the rod and the other to ground with the unit running, meter on AC volts.
A good one reads: 1 uA or greater is a proper flame circuit; the rod-to-ground method should read 5-150 V AC. Below range with a clean rod: check carbon build-up, wiring and ground before replacing parts.
Test values from images.tradeservice.com documentation - confirm against your model's own tech sheet.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.