Rinnai Water heater 00 Error Code

What the 00 code means

Scale build-up in the heat exchanger - the same alert as LC in its maintenance-history form: Rinnai's documentation substitutes 00 for LC in the unit's maintenance history, and older Rinnai manuals title the flush section "Error Code: LC or 00". Whether the display shows LC, an LC number, or 00 in the history, the fault and the remedy are identical: the heat exchanger must be flushed to prevent damage, and repeated scale codes will eventually lock the water heater out. Documented for the SENSEI RX/CX and Non-SENSEI series.

Likely causes

  1. Hard water scale build-up inside the heat exchanger
  2. Flush/service overdue

How to fix it — step by step

  1. Find the isolation (service) valves on the plumbing directly below the unit - hot (red handle) and cold (blue handle), each with a capped service port. Flush the heat exchanger: isolate the unit with those valves, connect a circulation pump to push descaling solution in through the cold service port and a return hose from the hot service port to a bucket, and circulate (about an hour). If the unit has no isolation valves fitted, they have to be added before flushing is possible.
  2. Treat hard water. Hard water must be treated to prevent scale build-up or damage, and scale damage is the point of the lockout feature.
  3. To run temporarily until the flush, push the On/Off button on the temperature controller five times within five seconds - the heater runs about 70 hours, then locks out with the next LC number. Temporary resets only buy time; the rising count is the confirmation the flush is overdue.
  4. After a proper flush the LC count resets automatically on RX/CX; if not, hold PC Board switches A and B together for five seconds to return the count to 0 (on older non-SENSEI products, cycling power resets LC).
  5. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the code should stay clear through the whole draw. If it comes back, the flush did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 00 code

Parts run $300–$900Typical pro repair $228–$1,017
  • Heat exchanger descaling flush kit (circulation pump and descaling solution)$300–$900Shop at Amazon

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manufacturer documentation

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Rinnai Water heater error codes

See all Rinnai water heater codes & guides →