Rinnai Water heater 19 Error Code

What the 19 code means

Electrical grounding fault. If code 19 appears immediately after water flow begins with no flame in the burner box, there is an electrical short in a component in the DC circuit.

Likely causes

  1. Electrical short in a wiring harness, water flow control, bypass valve or other DC component
  2. Grounding fault in the heater circuit

How to fix it — step by step

  1. Check all components for an electrical short and verify all ground connections
  2. Track the short down by unplugging one component at a time and cycling the heater - if it cycles three times after a component is unplugged, the short is in that device
  3. Replace the shorted component; if grounding of the supply circuit is in doubt, have a licensed electrician correct it
  4. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 19 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 19 code

No specific replacement part is documented for this fault. If the checks above do not clear it, your water heater likely needs to be disassembled and an internal part replaced - and since the manufacturer publishes no procedure for that, it is the point where most owners hand it to a repair shop.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manufacturer documentation

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Rinnai Water heater error codes

See all Rinnai water heater codes & guides →