Lochinvar Knight 81-286 (SMART SYSTEM) Common Problems
Find your problem in the list below. Each page explains the most likely causes, step-by-step checks you can do yourself, when to call a pro, and the parts that commonly resolve it. 28 problems covered.
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
| Problem | What it means | Check first | |
|---|---|---|---|
| Anti-cycling | Anti-cycling is not a component failure. The main control board has received a call for heat too quickly… | Call for heat repeated too quickly after the previous call ended | › |
| APS / HEX Temp Sw Open | APS / HEX Temp Sw Open is a manual reset lockout raised when either the air pressure switch contacts are open… | Air pressure switch contacts open | › |
| Blocked Drain SW | Blocked Drain SW is a manual reset lockout raised when the blocked drain switch detects excessive condensate… | Excessive condensate build up inside the unit | › |
| Delta T High | Delta T High is raised when the temperature rise across the heat exchanger has exceeded the set parameters… | Temperature rise across the heat exchanger exceeded set parameters | › |
| Fan Speed Low / High | Fan Speed Low / High, also shown as Fan Low/High, is a manual reset lockout raised when the actual fan RPM is… | Actual fan RPM 30 percent lower or higher than called for | › |
| Fatal Error | Fatal Error is raised when the control module has detected parameter settings that are out of range. The… | Control module detected parameter settings out of range | › |
| Flame Fail Ign | Flame Fail Ign is a manual reset lockout raised when the unit has failed to prove main burner ignition after… | Failed to prove main burner ignition after four attempts | › |
| Flame Sequence | Flame Sequence is a manual reset lockout raised when the flame detector circuit is seeing a flame signal… | Flame signal present with no flame | › |
| Flow Switch/LWCO | Flow Switch/LWCO is a manual reset lockout raised when either the optional flow switch or the optional low… | Flow switch not making | › |
| Flue Sensor Fault | Flue Sensor Fault is a manual reset lockout raised when the control reads the flue sensor as open or shorted.… | Control reads the flue sensor as open or shorted | › |
| Flue Temp Diff | Flue Temp Diff is a manual reset lockout raised when the control module reads an excessive temperature… | Excessive temperature difference between the two sensors | › |
| Flue Temp High | Flue Temp High is raised when the stack temperature has exceeded the set parameters for the boiler. It… | Stack temperature exceeded the set parameters | › |
| Flue Temp Limit | Flue Temp Limit is a manual reset lockout raised when the stack temperature has exceeded the Flue Temp Limit… | Stack temperature exceeded the Flue Temp Limit set parameters | › |
| Gas Pressure SW | Gas Pressure SW is a manual reset lockout. Either the optional manual reset low gas pressure switch or the… | Low or high gas pressure switch tripped | › |
| GV/Relay Fail | GV/Relay Fail is a manual reset lockout raised when the main control board did not detect the gas valve. The… | Main control board did not detect the gas valve | › |
| Inlet Sensor Fault | Inlet Sensor Fault is a manual reset lockout raised when the control reads the inlet sensor as open or… | Control reads the inlet sensor as open or shorted | › |
| Louver Proving Sw | Louver Proving Sw is a manual reset lockout raised when an optional remote proving switch is not making. The… | Optional remote proving switch not making | › |
| Memory Error | Memory Error is raised when a lockout occurs at the same time as a power outage. The control's memory of the… | Lockout occurred at the same time as a power outage | › |
| Outlet ARHL | Outlet ARHL means the outlet water temperature has exceeded the setting of the automatic reset high limit.… | Outlet temperature exceeded the automatic reset high limit setting | › |
| Outlet MRHL | Outlet MRHL is a manual reset lockout raised when the outlet water temperature has exceeded the setting of… | Outlet temperature exceeded the manual reset high limit setting | › |
| Outlet Sensor Fault | Outlet Sensor Fault is a manual reset lockout raised when the control reads the outlet sensor as open or… | Control reads the outlet sensor as open or shorted | › |
| Outlet Temp Diff | Outlet Temp Diff is a manual reset lockout raised when the control module reads an excessive temperature… | Excessive temperature difference between the two sensors | › |
| Outlet Temp High | Outlet Temp High is raised when the outlet water temperature has exceeded the maximum outlet water… | Outlet water temperature exceeded the maximum outlet water temperature | › |
| Parameters Progr | Parameters Progr is a manual reset message, not a failure. After parameters are downloaded from a laptop, the… | Parameters downloaded from a laptop, main control board awaiting reset | › |
| Rem Ctrl Flt | Rem Ctrl Flt is raised when the external control is cycling too often. The boiler is reporting the behaviour… | External control cycling too often | › |
| Sensor Open | Sensor Open is a manual reset lockout raised when either the inlet water or outlet water temperature sensor… | Inlet water temperature sensor disconnected | › |
| Sensor Shorted | Sensor Shorted is a manual reset lockout raised when either the inlet water or outlet water temperature… | Inlet water temperature sensor shorted | › |
| Service Blk | Service Blk is a blocking message shown while the unit is in Service Mode and the outlet temperature has… | Unit in Service Mode with outlet temperature over 185°F | › |
All Lochinvar boiler models & codes →
Looking for a part?
Once you know the part you need, browse Lochinvar Knight 81-286 (SMART SYSTEM) replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.