Lochinvar Boiler Knight 81-286 (SMART SYSTEM) Parameters Progr
What this problem usually means
Parameters Progr is a manual reset message, not a failure. After parameters are downloaded from a laptop, the main control board must be reset before it will run on the new set. Pressing the ENTER/RESET button on the SMART SYSTEM display panel completes the programming.
Likely causes
- Parameters downloaded from a laptop, main control board awaiting reset
How to fix it — step by step
- Record the fault before resetting: write down 'Parameters Progr' exactly as shown on the SMART SYSTEM display, and note that most Knight lockouts need a manual reset with the RESET button on the SMART SYSTEM display after the condition is corrected.
- Safety: shut the boiler down, isolate power and close the gas shut-off valve before opening the cabinet or testing wiring. Gas pressure, gas valve and combustion checks are qualified technician work.
- Locate the part: the message is generated by the main control board after a laptop parameter download, and it is read and cleared on the SMART SYSTEM display panel.
- Test: confirm a parameter download has just been performed by whoever is programming the boiler. A download in progress fully explains the message; the message appearing with no download is a reason to have the parameter set checked.
- End at the resolution: press the ENTER/RESET button on the SMART SYSTEM display panel. The boiler then runs on the downloaded parameters.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the fault is internal - there is no documented owner fix beyond the steps above. If you're not comfortable taking it apart yourself, a repair shop is the next step.
Parts that commonly fix it
This fault usually does not need a replacement part - the fix is in the steps above. If your boiler does need a part, start with the link above.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.
Related Lochinvar Boiler Knight 81-286 (SMART SYSTEM) problems
- Rem Ctrl Flt
- Sensor Open
- Sensor Shorted
- Service Blk
- Anti-cycling
- APS / HEX Temp Sw Open
- Blocked Drain SW
- Delta T High
- Fan Speed Low / High
- Fatal Error
- Flame Fail Ign
- Flame Sequence
See all Lochinvar Knight 81-286 (SMART SYSTEM) codes & guides →