Lochinvar Boiler Knight 81-286 (SMART SYSTEM) Sensor Open

What this problem usually means

Sensor Open is a manual reset lockout raised when either the inlet water or outlet water temperature sensor has been disconnected. The control has lost a water temperature it needs, so it locks out rather than fire blind. The sensors and their wiring are checked and the sensor resistance is compared with the sensor tables before anything is replaced.

Likely causes

  1. Inlet water temperature sensor disconnected
  2. Outlet water temperature sensor disconnected
  3. Damaged sensor wiring

How to fix it — step by step

  1. Record the fault before resetting: write down 'Sensor Open' exactly as shown on the SMART SYSTEM display, and note that most Knight lockouts need a manual reset with the RESET button on the SMART SYSTEM display after the condition is corrected.
  2. Safety: shut the boiler down, isolate power and close the gas shut-off valve before opening the cabinet or testing wiring. Gas pressure, gas valve and combustion checks are qualified technician work.
  3. Locate the parts: the inlet and outlet water temperature sensors are fitted in the boiler waterways and wired to the main control board, and the fault is read on the SMART SYSTEM display.
  4. Test: check both sensors and their associated wiring for disconnection or damage and repair or reconnect what is found. Then measure the resistance of the sensors and compare it with the sensor tables; a sensor reading open against the table is the pinpoint.
  5. End at the fix: repair the wiring or replace the sensor the resistance test condemns, then press RESET on the SMART SYSTEM display.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $25–$80
  • Inlet water temperature sensor$25–$80Shop at Amazon
  • Outlet water temperature sensor$25–$80Shop at Amazon
  • Tools for this job, if you need them$15–$65

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.

Related Lochinvar Boiler Knight 81-286 (SMART SYSTEM) problems