Lochinvar Boiler Common Problems

Find your problem in the list below. Each page explains the most likely causes, step-by-step checks you can do yourself, when to call a pro, and the parts that commonly resolve it. 28 problems covered.

Finding your model number: it is on the rating plate on the boiler jacket, often behind the front panel.

Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.

Knight with SMART SYSTEM (plain-language messages)

The Knight's SMART SYSTEM control reports faults as plain-language status messages on the display (for example Gas Pressure SW) rather than numbered codes; each message in the manual's troubleshooting table states whether it is a manual-reset lockout or an auto-reset condition.

ProblemWhat it meansCheck first
Anti-cyclingAnti-cycling is not a component failure. The main control board has received a call for heat too quickly…Call for heat repeated too quickly after the previous call ended›
APS / HEX Temp Sw OpenAPS / HEX Temp Sw Open is a manual reset lockout raised when either the air pressure switch contacts are open…Air pressure switch contacts open›
Blocked Drain SWBlocked Drain SW is a manual reset lockout raised when the blocked drain switch detects excessive condensate…Excessive condensate build up inside the unit›
Delta T HighDelta T High is raised when the temperature rise across the heat exchanger has exceeded the set parameters…Temperature rise across the heat exchanger exceeded set parameters›
Fan Speed Low / HighFan Speed Low / High, also shown as Fan Low/High, is a manual reset lockout raised when the actual fan RPM is…Actual fan RPM 30 percent lower or higher than called for›
Fatal ErrorFatal Error is raised when the control module has detected parameter settings that are out of range. The…Control module detected parameter settings out of range›
Flame Fail IgnFlame Fail Ign is a manual reset lockout raised when the unit has failed to prove main burner ignition after…Failed to prove main burner ignition after four attempts›
Flame SequenceFlame Sequence is a manual reset lockout raised when the flame detector circuit is seeing a flame signal…Flame signal present with no flame›
Flow Switch/LWCOFlow Switch/LWCO is a manual reset lockout raised when either the optional flow switch or the optional low…Flow switch not making›
Flue Sensor FaultFlue Sensor Fault is a manual reset lockout raised when the control reads the flue sensor as open or shorted.…Control reads the flue sensor as open or shorted›
Flue Temp DiffFlue Temp Diff is a manual reset lockout raised when the control module reads an excessive temperature…Excessive temperature difference between the two sensors›
Flue Temp HighFlue Temp High is raised when the stack temperature has exceeded the set parameters for the boiler. It…Stack temperature exceeded the set parameters›
Flue Temp LimitFlue Temp Limit is a manual reset lockout raised when the stack temperature has exceeded the Flue Temp Limit…Stack temperature exceeded the Flue Temp Limit set parameters›
Gas Pressure SWGas Pressure SW is a manual reset lockout. Either the optional manual reset low gas pressure switch or the…Low or high gas pressure switch tripped›
GV/Relay FailGV/Relay Fail is a manual reset lockout raised when the main control board did not detect the gas valve. The…Main control board did not detect the gas valve›
Inlet Sensor FaultInlet Sensor Fault is a manual reset lockout raised when the control reads the inlet sensor as open or…Control reads the inlet sensor as open or shorted›
Louver Proving SwLouver Proving Sw is a manual reset lockout raised when an optional remote proving switch is not making. The…Optional remote proving switch not making›
Memory ErrorMemory Error is raised when a lockout occurs at the same time as a power outage. The control's memory of the…Lockout occurred at the same time as a power outage›
Outlet ARHLOutlet ARHL means the outlet water temperature has exceeded the setting of the automatic reset high limit.…Outlet temperature exceeded the automatic reset high limit setting›
Outlet MRHLOutlet MRHL is a manual reset lockout raised when the outlet water temperature has exceeded the setting of…Outlet temperature exceeded the manual reset high limit setting›
Outlet Sensor FaultOutlet Sensor Fault is a manual reset lockout raised when the control reads the outlet sensor as open or…Control reads the outlet sensor as open or shorted›
Outlet Temp DiffOutlet Temp Diff is a manual reset lockout raised when the control module reads an excessive temperature…Excessive temperature difference between the two sensors›
Outlet Temp HighOutlet Temp High is raised when the outlet water temperature has exceeded the maximum outlet water…Outlet water temperature exceeded the maximum outlet water temperature›
Parameters ProgrParameters Progr is a manual reset message, not a failure. After parameters are downloaded from a laptop, the…Parameters downloaded from a laptop, main control board awaiting reset›
Rem Ctrl FltRem Ctrl Flt is raised when the external control is cycling too often. The boiler is reporting the behaviour…External control cycling too often›
Sensor OpenSensor Open is a manual reset lockout raised when either the inlet water or outlet water temperature sensor…Inlet water temperature sensor disconnected›
Sensor ShortedSensor Shorted is a manual reset lockout raised when either the inlet water or outlet water temperature…Inlet water temperature sensor shorted›
Service BlkService Blk is a blocking message shown while the unit is in Service Mode and the outlet temperature has…Unit in Service Mode with outlet temperature over 185°F›

Common questions

Why does my Lochinvar Knight show words instead of a code?
That is the SMART SYSTEM control's design: faults are spelled out as status messages. Gas Pressure SW, for example, is a manual-reset lockout telling you a gas pressure switch - the optional manual-reset low gas pressure switch or the high gas pressure switch - has opened.

Looking for a part?

Once you know the part you need, browse Lochinvar Boiler replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.