Lochinvar Boiler Knight 81-286 (SMART SYSTEM) Outlet Temp High
What this problem usually means
Outlet Temp High is raised when the outlet water temperature has exceeded the maximum outlet water temperature. The corrective set is the same water side proof used for the high limit faults, full and purged system, correct piping, a powered and correctly sized boiler pump, and finally the main control board. A boiler that overheats its outlet is not moving its heat away.
Likely causes
- Outlet water temperature exceeded the maximum outlet water temperature
- System not full of water or air not purged
- Boiler piped incorrectly
- Boiler pump not running, wrong speed or wrong size
- Faulty main control board
How to fix it — step by step
- Record the fault before resetting: write down 'Outlet Temp High' exactly as shown on the SMART SYSTEM display, and note that most Knight lockouts need a manual reset with the RESET button on the SMART SYSTEM display after the condition is corrected.
- Safety: shut the boiler down, isolate power and close the gas shut-off valve before opening the cabinet or testing wiring. Gas pressure, gas valve and combustion checks are qualified technician work.
- Locate the parts: the outlet sensor is in the boiler outlet waterway, the boiler pump is in the boiler loop, and the fault is read on the SMART SYSTEM display.
- Test: verify the system is full of water and purged and the boiler is piped properly. Check 120 vac to the boiler pump on a call for heat and work back to the main control board if it is absent; if voltage is present and the pump does not run, the pump is condemned, and its speed and size are checked against the boiler's pump specifications.
- End at the fix: correct the water, piping or pump fault, or replace the main control board if it never powers a proven pump, then reset. Repeated Outlet Temp High with flow proven is a technician investigation, not a reset routine. → Shop the main control board at Amazon
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Boiler pump.
Shop the Boiler pump at Amazon
Also tied to this fault: Main control board - Shop at Amazon
Parts that commonly fix it
- Boiler pumpShop at Amazon
- Main control boardShop at Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.
Related Lochinvar Boiler Knight 81-286 (SMART SYSTEM) problems
- Parameters Progr
- Rem Ctrl Flt
- Sensor Open
- Sensor Shorted
- Service Blk
- Anti-cycling
- APS / HEX Temp Sw Open
- Blocked Drain SW
- Delta T High
- Fan Speed Low / High
- Fatal Error
- Flame Fail Ign
See all Lochinvar Knight 81-286 (SMART SYSTEM) codes & guides →