Lochinvar Boiler Knight 81-286 (SMART SYSTEM) Anti-cycling Error Code

What the Anti-cycling code means

Anti-cycling is not a component failure. The main control board has received a call for heat too quickly after the previous call for heat ended, so it holds the boiler off on purpose. The control releases the call after a set time period, or sooner if the outlet temperature drops quickly enough.

Likely causes

  1. Call for heat repeated too quickly after the previous call ended
  2. External control short cycling the boiler

How to fix it — step by step

  1. Record the fault before resetting: write down 'Anti-cycling' exactly as shown on the SMART SYSTEM display, and note that most Knight lockouts need a manual reset with the RESET button on the SMART SYSTEM display after the condition is corrected.
  2. Safety: shut the boiler down, isolate power and close the gas shut-off valve before opening the cabinet or testing wiring. Gas pressure, gas valve and combustion checks are qualified technician work.
  3. Locate the part: there is no failed part to locate. The message is generated by the main control board and read on the SMART SYSTEM display, and the thing to inspect is the external control making the calls for heat.
  4. Test: time the calls. Calls that return within a very short off period confirm anti-cycling is doing its job; the fault to hunt is why the external control or system load is short cycling, not the boiler.
  5. End at the resolution: wait for the control to release the call, which it does after its set time or on a fast outlet temperature drop. If short cycling continues, correct the external control settings or system cause rather than replacing boiler parts.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the Anti-cycling code

This fault usually does not need a replacement part - the fix is in the steps above. If your boiler does need a part, start with the link above.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.

Related Lochinvar Boiler Knight 81-286 (SMART SYSTEM) error codes

See all Lochinvar Knight 81-286 (SMART SYSTEM) codes & guides →