Rheem Water heater Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 56 codes covered.
Not sure of the code? Tap along with it
If your Rheem Water heater blinks or beeps a pattern instead of showing a code, tap the button in time with each blink or beep. A pause longer than a second and a half starts a new group - we will match the rhythm to a code.
Your taps: -
Finding your model number: it is on the unit's rating plate.
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
All models
| Code | What it means | Check first | |
|---|---|---|---|
| 03 | Manifold setting failure (manifolded / multiple-unit installations only — EZ-Link, MIC-6 or MIC-185 systems).… | Connection cable between the water heaters and the manifold controller loose or | › |
| 05 | Low heat exchanger temperature detected (warning code). The heat exchanger thermistor is reading abnormally… | Scale buildup on the heat exchanger thermistor skewing its reading | › |
| 10 | Incorrect inlet air volume (warning code). The blower is not moving enough combustion air — the heater was… | Vent termination blocked (inlet or exhaust side) | › |
| 10 flashes | Chamber temperature shutdown. The status light blinks red ten times every three seconds: combustion chamber… | Overheating inside the combustion chamber (blocked combustion air, flammable vapors, or | › |
| 11 | Flame not detected by the flame rod — ignition failure. The heater attempted ignition twice and the flame rod… | Gas supply pressure out of range or gas shut-off not fully open | › |
| 12 | Flame detected, then lost. The heater lit and the flame rod sensed flame, then the flame was lost during… | Low or interrupted gas supply pressure, including LP tank running low | › |
| 14 | Overheat limiter (OHL) is active. The overheat limiter wrapped on the heat exchanger has opened or broken… | Broken or heat-damaged overheat limiter (OHL) | › |
| 15 | Excessively hot water detected. Outlet and/or heat exchanger water temperature stayed above 207°F (97°C) for… | Sediment / lime buildup in the heat exchanger causing hot spots | › |
| 16 | Outlet water temperature is above the set point. The outlet thermistor reports water hotter than the… | Outlet thermistor scaled or failing, misreporting temperature | › |
| 17 | Leak sensor has detected water. The built-in leak sensor (Wi-Fi models) reports water where it should not be… | Active water leak at the heater, its connections, or the heat exchanger | › |
| 1L | Lime (scale) buildup detected inside the heat exchanger. The control board has detected mineral deposits… | Hard-water scale accumulated in the heat exchanger from missed flushing | › |
| 2 flashes | Thermopile voltage low, with the pilot lit. The status light blinks red twice every three seconds: the… | Loose or poorly connected thermopile connector at the gas control | › |
| 24 | DIP switch malfunction signal generated from the controller: the UP/DOWN buttons on the built-in controller… | Buttons held down accidentally (cleaning, bumped controller) | › |
| 28 | Low heat exchanger temperature detected (error code). The heat exchanger thermistor kept reading low… | Scale buildup on the heat exchanger thermistor | › |
| 29 | Condensate is not draining from the collector. The electrode in the built-in drain trap senses the trap is… | Condensate drain line blocked internally or externally | › |
| 31 | Inlet thermistor malfunction. The control detected an error in the inlet thermistor circuit — open, shorted… | Scale buildup or debris on the inlet thermistor skewing its reading | › |
| 32 | Heat exchanger thermistor malfunction. The control detected an error in the heat exchanger thermistor circuit… | Scale buildup or debris on the heat exchanger thermistor skewing its reading | › |
| 33 | Outlet thermistor malfunction. The control detected an error in the outlet thermistor circuit — open… | Scale buildup or debris on the outlet thermistor skewing its reading | › |
| 34 | Ambient / air supply thermistor malfunction. The control detected an error in the ambient / air supply… | Scale buildup or debris on the ambient / air supply thermistor skewing its reading | › |
| 35 | Improper thermistor connection. One or more of the heater's three thermistors — inlet, outlet, or heat… | Loose connector C on the control board | › |
| 4 flashes | High water temperature limit tripped. The status light blinks red four times every three seconds: the… | Thermostat failed and overheated the tank | › |
| 5 flashes | Water temperature sensor failure. The status light blinks red five times every three seconds: the temperature… | Failed temperature sensor in the gas control well | › |
| 51 | Main gas solenoid valve (SV) malfunction. The flame rod is still detecting flame a few seconds after the… | Loose or dirty flame rod connections (connectors 'D' and 'G') giving a false flame | › |
| 52 | Proportional gas valve malfunction. The flame rod detects flame a few seconds after the water heater turns… | Loose connector 'D' or loose gas valve molex connections (the red and black wires) | › |
| 61 | Blower motor fault — blower motor speed is incorrect for combustion (the Use & Care chart lists code 61 as a… | Blocked air intake or vent exhaust starving / overloading the blower | › |
| 63 | Recirculation pump operation abnormality. The built-in recirculation pump is not moving water as commanded —… | Blockage in the recirculation loop preventing the pump from flowing water | › |
| 65 | Water motor failed — water volume control fault. The motorized water volume control valve that meters flow… | Failed water volume control (water control) assembly — the motor is not driving the | › |
| 66 | Bypass motor failed — faulty water bypass motor. The motor that drives the water bypass valve (used to temper… | Failed bypass motor | › |
| 7 flashes | Combination gas control (thermostat) failure. The status light blinks red seven times every three seconds… | Internal electronic/mechanical failure of the gas control valve | › |
| 70 | Microcomputer abnormality. The microcomputer on the control board is not working properly — a board-level… | Failed control board (microcomputer) | › |
| 71 | Solenoid valve (SV) circuit failure. The gas solenoid valve is not working properly and the control cannot… | Loose or damaged solenoid valve wiring, or a poor connector 'D' connection | › |
| 72 | Flame rod detected flame before ignition. The flame rod reports flame before the igniter has even fired —… | Loose or dirty flame rod connection (connector 'G' and the flame rod terminal) giving a | › |
| 76 | Built-in display (or remote controller) to water heater communication failure. The controller and the control… | Loose or damaged user-interface wiring (connector 'A' on built-in-display units | › |
| 79 | Blower motor current failure. When the blower operates, its current draw is not the value the control expects… | Dirty blower motor and blower motor housing restricting the motor | › |
| 8 flashes | False pilot flame signal (flame sense error). The status light blinks red eight times every three seconds… | Flame sensor / pilot assembly fault giving a false signal | › |
| 80 | Detected flame presence after closing solenoid valves. A few seconds after the solenoid valves close, the… | Solenoid valves not seating closed — gas leaking through after shutdown | › |
| 82 | Installed gas chip error. The gas chip on the control board — the plug that tells the control which gas type… | Wrong gas chip installed for the heater's gas type (for example after an NG-to-LP | › |
| 88 | Maintenance reminder — time to flush the heat exchanger and/or replace the water treatment filter. The heater… | Heat exchanger flushing interval reached | › |
| 89 | High exhaust temperature detected. The over-temperature limit switch on the secondary heat exchanger has… | Venting problem — blocked, restricted, or incorrectly installed venting holding heat in | › |
| 9 flashes | Chamber sensor failure. The status light blinks red nine times every three seconds: the combustion chamber… | Failed combustion chamber sensor | › |
| 90 | Blockage in venting detected (before the unit goes to ignition). The control proved a restriction in the air… | Air intake or vent exhaust opening blocked (snow, leaves, nests, debris) | › |
| 99 | Blockage in venting detected (after the unit shut down). The control proved a restriction in the air intake… | Air intake or vent exhaust opening blocked (snow, leaves, nests, debris) | › |
| No hot water | The gas tank heater is delivering no hot water at all. On a standing-pilot Rheem the bulletin reduces this to… | Gas supply turned off to the heater | › |
| Not enough hot water | The gas tank heater makes hot water but runs out too fast or never gets hot enough. The bulletin's cause list… | Thermostat set too low | › |
| P1 | Not enough water flow to operate the unit. Flow through the heater is below the roughly 0.4 GPM minimum… | Debris in the inlet water filter or heat exchanger restricting flow | › |
| Pilot light won't stay lit | The pilot lights while the control knob is held down but goes out when the knob is released (or will not… | Defective thermocouple | › |
| Rumbling noise | Rumbling, popping, or sizzling noise from the tank while it heats. Scale and sediment built up in the bottom… | Scale or sediment buildup in the bottom of the tank | › |
| Rumbling or Popping Noises | Rumbling, popping or banging from a Rheem tank while it heats is almost always sediment: minerals settle on… | Sediment and mineral scale settled on the tank bottom, with water trapped beneath | › |
| Rusty or smelly water | Hot water that is rusty/black, or smells of rotten eggs. Rusty water means the sacrificial anode rod that… | Anode rod dissolved / consumed | › |
| Smelly Water | Rotten-egg or sulfur-smelling hot water from a Rheem tank is hydrogen sulfide gas made inside the tank… | Sulfate-reducing bacteria in the tank reacting with sulfate in the supply water | › |
| Water heater leaking | Water pooling at or dripping from the gas tank heater. The bulletin warns first not to confuse normal T&P… | Cold-in or hot-out pipe joints leaking at the tank top | › |
| Water Too Hot | Water that is too hot from a Rheem tank is a scald hazard first and a fault second. Start with the setting —… | Thermostat simply set too high — many tanks are factory-set near 140F, above the | › |
| Won't Turn On | For a heater that is not producing heat or not turning on, the causes are: a blown fuse or tripped breaker… | Blown fuse or tripped breaker, or the electric supply / disconnect switch off — the | › |
Electric tank
| Problem | What it means | Check first | |
|---|---|---|---|
| No hot water | The electric tank heater delivers no hot water at all. Rheem's electric Trouble Shooting Guide works it in… | Manual switch turned off or disconnect off | › |
| Noisy heating elements | The electric heating elements are noisy during heating. Rheem's electric Trouble Shooting Guide gives one… | Scale build-up on the heating elements from hard water conditions | › |
| Not enough hot water | The electric tank heater makes some hot water but not enough. Rheem's electric Trouble Shooting Guide lists… | Defective heating element (one of two elements out — typically the lower element | › |
Once you know the part you need, browse Rheem Water heater replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.