Rheem Water heater 99 Error Code

What the 99 code means

Blockage in venting detected (after the unit shut down). The control proved a restriction in the air intake or vent exhaust — the Use & Care chart lists codes 90/99 together for a blocked intake or exhaust opening, or vent pipes on the termination not connected properly — and will not run the burner against a blocked flue.

Likely causes

  1. Air intake or vent exhaust opening blocked (snow, leaves, nests, debris)
  2. Vent pipes at the termination not connected properly or disconnected
  3. Crushed, sagged, or obstructed vent run

How to fix it — step by step

  1. Inspect the air intake and vent exhaust openings outside and remove any blockage; keep 12 in. (30 cm) of clearance at the air intake.
  2. Inspect the vent termination and confirm the vent pipes are connected properly; reconnect any separated joint with the manufacturer-approved vent material only.
  3. Inspect the indoor vent run for crushing, sagging condensate traps, or obstructions and correct them.
  4. Restart the heater per the reset procedure and run a hot water draw; if the code returns with visibly clear, connected venting, contact a dealer or qualified service technician to test the blower and pressure proving circuit.
  5. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 99 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 99 code

No specific replacement part is documented for this fault. If the checks above do not clear it, your water heater likely needs to be disassembled and an internal part replaced - and since the manufacturer publishes no procedure for that, it is the point where most owners hand it to a repair shop.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manufacturer documentation

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Rheem Water heater error codes

See all Rheem water heater codes & guides →