Rheem Water heater 11 Error Code

What the 11 code means

Flame not detected by the flame rod — ignition failure. The heater attempted ignition twice and the flame rod never sensed a flame, so the control locked out instead of continuing to feed gas to an unlit burner.

Likely causes

  1. Gas supply pressure out of range or gas shut-off not fully open
  2. Gas filter at the heater's gas connection blocked by debris
  3. Vent termination blocked or venting disconnected
  4. Dirty or failed igniter rod / igniter coil — no spark
  5. Dirty or failed flame rod — flame present but not sensed
  6. Failed gas valve solenoids or control board

How to fix it — step by step

  1. Reset first: turn off all hot water faucets, turn the heater OFF at the built-in or remote controller, wait about 5 minutes, turn it back ON, and open a hot water faucet to recheck the display.
  2. Check the gas shut-off valve at the heater and open it completely; confirm other gas appliances in the home are working.
  3. Check gas supply pressure at the heater connection: Natural Gas 4.0–10.5 in. W.C., LP 8.0–13.0 in. W.C., checking both static (standby) and dynamic (max combustion) pressure.
  4. Inspect the gas filter at the gas connection and clean out any foreign substance blocking it.
  5. Inspect the vent connections and termination; reconnect venting or clear blockages on both inlet and exhaust sides.
  6. Watch for spark through the sight glass during ignition. No spark: power OFF, reseat the white Molex on the igniter coil, the igniter cable on the igniter rod, and connector O, then retest. Measure 108–132 AC volts across the two gray wires on connector O while attempting ignition — no voltage means replace the control board; voltage present means remove and clean the igniter rod, and if there is still no spark, replace the igniter coil and igniter rod. → Shop the igniter coil at Amazon → Shop the igniter rod at Amazon
  7. Spark visible but no flame detection: reseat connector G and the flame rod terminal, check flame rod status in maintenance mode (0Y = 01 detecting, 00 not detecting), remove and clean the flame rod, and retest.
  8. Check gas valve solenoid resistances at connector D (each solenoid 10–50 ohms) and solenoid drive voltage (5–15 DC volts; inlet solenoid 11–17 DC volts). Out-of-spec solenoids mean replace the gas valve; correct voltages with a clean, working flame rod and persistent code 11 mean replace the control board. → Shop the control board at Amazon → Shop the gas valve at Amazon
  9. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 11 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 11 code

Typical pro repair $228–$1,017

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manufacturer documentation

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Rheem Water heater error codes

See all Rheem water heater codes & guides →