Rheem Water heater 79 Error Code
What the 79 code means
Blower motor current failure. When the blower operates, its current draw is not the value the control expects — the motor is dirty, failing, or not being driven correctly — so the heater displays 79 and shuts down.
Likely causes
- Dirty blower motor and blower motor housing restricting the motor
- Loose connector 'K' connection at the control board or blower motor
- Failing blower motor
- Failed control board blower drive circuit
How to fix it — step by step
- Access for the board-level checks below: switch the power OFF at the unit and remove the front cover (a screw at each corner) - the control board and its connectors are behind it. Close the gas and water shut-off valves before disconnecting any gas or water part, and let internal parts cool before handling them
- Turn power OFF. Remove and reinsert connector 'K'. Remove the blower motor (three screws) and clean the blower motor and the blower motor housing. Reassemble, turn power ON, and operate the unit — if 79 clears, it was a loose connection or a dirty blower.
- If 79 returns, press and hold the Max button at the top of the control board and measure DC voltage between the #6 wire (red) and the #4 wire (black) at connector 'K' (outdoor units: #6 white and #4 blue): specification is 144-192 DC volts. Out of range — recheck connector 'K' and retry; if 79 still appears, replace the control board. → Shop the control board at Amazon
- With Max held, measure between the #1 wire (blue) and the #4 wire (black) at connector 'K' (outdoor units: #1 yellow and #4 blue) for 12-18 DC volts, and confirm the pulse signal reads 4-10 DC volts. A failed reading after rechecking connector 'K' means replace the control board.
- Turn power OFF then ON, hold Max again, and measure between the #3 wire (white) and the #4 wire (black) at connector 'K' (outdoor units: #3 red and #4 blue). If 79 still appears after these checks, replace the blower motor. → Shop the blower motor at Amazon
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 79 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the blower motor.
Shop the blower motor at Amazon
Also tied to this fault: control board - Shop at Amazon
Parts that commonly fix the 79 code
- blower motor$100–$300Shop at Amazon
- control board$100–$300Shop at Amazon
- Tools for this job, if you need them$10–$40
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.