Rheem Water heater Pilot light won't stay lit
What this problem usually means
The pilot lights while the control knob is held down but goes out when the knob is released (or will not light at all). The thermopile/thermocouple safety circuit is not proving flame, so the gas control correctly refuses to keep the pilot valve open.
Likely causes
- Defective thermocouple
- Poor thermocouple connection at the gas valve
- Thermocouple tip not immersed in the pilot flame
- Pilot burner orifice or pilot tube partially clogged, giving a weak flame
- Defective safety magnet assembly inside the gas valve
- Clogged flueway restricting draft
- Venting downdraft or other improper draft blowing the pilot out
- Improper gas pressure
- Air in the gas line (new install / after gas work)
How to fix it — step by step
- Follow the lighting instructions on the heater exactly: knob to PILOT, hold it fully down, light the pilot, and keep holding for a full minute after it lights before releasing slowly.
- Look at the pilot flame through the sight glass in the burner door at the base of the tank: it should be strong and blue and wrap the tip of the thermocouple. The thermocouple is the thin copper line running from the back of the gas control valve (front of the tank) down to the pilot assembly inside the burner compartment; reposition its tip so it is immersed in the flame if it sits at the flame's edge.
- Tighten the thermocouple connection where it screws into the gas valve - a loose connection is a bulletin-listed cause.
- Inspect and clean the pilot supply tube and pilot burner orifice (reached through the burner access at the base of the tank); a lazy, small, or yellow flame will not heat the thermocouple enough.
- Check for drafts: confirm proper updraft venting and look for other drafts that can blow the pilot out.
- Inspect and clean the flueway through the tank if draft is poor - a clogged flue is a bulletin-listed cause of pilots dropping out.
- Test the thermocouple before replacing it: with the pilot lit, a closed-circuit reading at the gas valve of about 10 millivolts or more means the thermocouple is producing enough to hold the valve - if the pilot still drops with that reading, a tight connection and a good flame, the fault is inside the valve (next step). A reading well under that means the thermocouple is weak - replace it, accessing it through the burner door at the base of the tank. → Shop the thermocouple at Amazon
- If a new thermocouple does not hold the pilot, the safety magnet assembly has failed - the repair is replacement of the gas control valve, which is qualified-technician work. Air in the gas line and gas pressure checks are also technician work. → Shop the gas control valve (thermostat) at Amazon
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the thermocouple.
Shop the thermocouple at Amazon
Also tied to this fault: gas control valve (thermostat) - Shop at Amazon
Parts that commonly fix it
- thermocoupleShop at Amazon
- gas control valve (thermostat)$115–$500Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.