What the 35 code means

Improper thermistor connection. One or more of the heater's three thermistors — inlet, outlet, or heat exchanger — has a poor connection or is plugged into the wrong location, so the control cannot trust its temperature inputs.

Likely causes

  1. Loose connector C on the control board
  2. A thermistor Molex unplugged or only partly seated
  3. Thermistor Molexes swapped (inlet = white, outlet = black, heat exchanger = yellow)

How to fix it — step by step

  1. Access for the board-level checks below: switch the power OFF at the unit and remove the front cover (a screw at each corner) - the control board and its connectors are behind it. Close the gas and water shut-off valves before disconnecting any gas or water part, and let internal parts cool before handling them
  2. Turn power OFF and remove and reinsert connector C on the control board; restore power and check whether code 35 clears — a cleared code was a loose connection.
  3. If it returns, power OFF and remove and reinsert each thermistor Molex individually, confirming each is in its correct location by color: inlet thermistor — white Molex; outlet thermistor — black Molex; heat exchanger thermistor — yellow Molex.
  4. Restore power and operate the unit; test any thermistor that still errors using its individual code procedure (31 inlet, 33 outlet, 32 heat exchanger) and replace a thermistor that reads outside 7K–23K ohms. → Shop the heat exchanger thermistor at Amazon → Shop the outlet thermistor at Amazon
  5. If all connections and thermistors test good and code 35 persists, replace the control board. → Shop the control board at Amazon
  6. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 35 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 35 code

Parts run $25–$900Typical pro repair $228–$1,017

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.