What the 35 code means
Improper thermistor connection. One or more of the heater's three thermistors — inlet, outlet, or heat exchanger — has a poor connection or is plugged into the wrong location, so the control cannot trust its temperature inputs.
Likely causes
- Loose connector C on the control board
- A thermistor Molex unplugged or only partly seated
- Thermistor Molexes swapped (inlet = white, outlet = black, heat exchanger = yellow)
How to fix it — step by step
- Access for the board-level checks below: switch the power OFF at the unit and remove the front cover (a screw at each corner) - the control board and its connectors are behind it. Close the gas and water shut-off valves before disconnecting any gas or water part, and let internal parts cool before handling them
- Turn power OFF and remove and reinsert connector C on the control board; restore power and check whether code 35 clears — a cleared code was a loose connection.
- If it returns, power OFF and remove and reinsert each thermistor Molex individually, confirming each is in its correct location by color: inlet thermistor — white Molex; outlet thermistor — black Molex; heat exchanger thermistor — yellow Molex.
- Restore power and operate the unit; test any thermistor that still errors using its individual code procedure (31 inlet, 33 outlet, 32 heat exchanger) and replace a thermistor that reads outside 7K–23K ohms. → Shop the heat exchanger thermistor at Amazon → Shop the outlet thermistor at Amazon
- If all connections and thermistors test good and code 35 persists, replace the control board. → Shop the control board at Amazon
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 35 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the inlet thermistor.
Shop the inlet thermistor at Amazon
Also tied to this fault: outlet thermistor - Shop at Amazon; heat exchanger thermistor - Shop at Amazon; control board - Shop at Amazon
Parts that commonly fix the 35 code
- inlet thermistor$25–$80Shop at Amazon
- outlet thermistor$25–$80Shop at Amazon
- heat exchanger thermistor$300–$900Shop at Amazon
- control board$100–$300Shop at Amazon
- Tools for this job, if you need them$10–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.