Rheem Water heater 29 Error Code
What the 29 code means
Condensate is not draining from the collector. The electrode in the built-in drain trap senses the trap is full, or cannot sense the water level at all, so the condensing heater shuts down to keep condensate from backing into the unit.
Likely causes
- Condensate drain line blocked internally or externally
- Drain line pinched or kinked
- An added 'P' trap in the drain line air-locking the trap
- Protection plug on the drain connection never removed at installation (new installs)
How to fix it — step by step
- Check the drain connection at the bottom of the unit: on a new installation, confirm the protection plug was removed from the drain connection.
- Inspect the full condensate drain line for internal or external blockage and clear it.
- Straighten any pinched or kinked section of drain line so condensate flows freely downhill to the drain.
- Remove any 'P' trap added to the drain line — the heater has a built-in trap and the line must not have a second trap.
- Restart the heater and confirm condensate drains steadily while the burner runs; if code 29 returns with a clear, correctly routed line, have the trap electrode / drain trap serviced.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the fault is internal - there is no documented owner fix beyond the steps above. If you're not comfortable taking it apart yourself, a repair shop is the next step.
Parts that commonly fix the 29 code
This fault usually does not need a replacement part - the fix is in the steps above. If your water heater does need a part, start with the link above.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.