Rheem Water heater 15 Error Code
What the 15 code means
Excessively hot water detected. Outlet and/or heat exchanger water temperature stayed above 207°F (97°C) for more than 15 seconds, so the control shut the heater down on over-temperature.
Likely causes
- Sediment / lime buildup in the heat exchanger causing hot spots
- Gas supply pressure too high
- Blocked or disconnected venting
- Heat exchanger thermistor reading incorrectly
- Outlet thermistor reading incorrectly
How to fix it — step by step
- Inspect the vent connections and termination first; reconnect venting or clear blockages on both inlet and exhaust sides.
- Check gas supply pressure at the heater connection: Natural Gas 4.0–10.5 in. W.C., LP 8.0–13.0 in. W.C., static and dynamic.
- Flush the heat exchanger for sediment/lime buildup using the code 1L flushing procedure (vinegar circulation through the service valves).
- Access for the board-level checks below: switch the power OFF at the unit and remove the front cover (a screw at each corner) - the control board and its connectors are behind it. Close the gas and water shut-off valves before disconnecting any gas or water part, and let internal parts cool before handling them
- Test the heat exchanger thermistor using the code 32 procedure and the outlet thermistor using the code 33 procedure (7K–23K ohms at connector C); clean scale from a thermistor that reads out of range and replace it if it stays out of range. → Shop the heat exchanger thermistor at Amazon → Shop the outlet thermistor at Amazon
- Restart and monitor outlet temperature; do not return the heater to regular use until the over-temperature cause is found.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the heat exchanger thermistor.
Shop the heat exchanger thermistor at Amazon
Also tied to this fault: outlet thermistor - Shop at Amazon; white vinegar (food grade) - Shop at Amazon
Parts that commonly fix the 15 code
- heat exchanger thermistor$300–$900Shop at Amazon
- outlet thermistor$25–$80Shop at Amazon
- white vinegar (food grade)Shop at Amazon
- Tools for this job, if you need them$10–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.