Rheem Water heater 5 flashes
What it should look like on your machine
then it repeats
5 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
Water temperature sensor failure. The status light blinks red five times every three seconds: the temperature sensor built into the combination gas control well has failed, so the control cannot measure tank temperature and shuts down.
Likely causes
- Failed temperature sensor in the gas control well
- Damaged sensor wiring in the control
How to fix it — step by step
- The sensor that failed is built into the well of the combination gas control at the front of the tank — it is not serviced separately, so the repair is replacement of the gas control valve (thermostat) itself. → Shop the gas control valve (thermostat) at Amazon
- Replace it following this removal sequence: control knob to OFF, main gas supply OFF, tank drained, the control's wires and the pilot/manifold connections disconnected, and the old control unthreaded from the tank fitting (turn it with a pipe section threaded into its inlet, never a wrench on the body).
- Fit the new control with approved Teflon tape or pipe joint compound on the tank fitting, reconnect everything, turn the gas on and leak-test the supply connections, then fill the tank completely before lighting — never fire a dry tank.
- Relight per the label and, with the burner lit, brush leak-detection solution on the manifold and pilot connections; bubbles mean a leak to correct before the heater is left running. Finish with a full heating cycle and a temperature check at a faucet.
- If you hand it over, tell the technician: 5 flashes — temperature sensor failure in the gas control well — the control itself is the replacement part.
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the gas control valve (thermostat).
Parts that commonly fix it
- gas control valve (thermostat)$115–$500Shop at Amazon
- Tools for this job, if you need them$10–$20
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.