Rheem Water heater 05 Error Code
What the 05 code means
Low heat exchanger temperature detected (warning code). The heat exchanger thermistor is reading abnormally low temperature while the heater runs; if the low reading continues, the warning escalates to error code 28 and the unit shuts down.
Likely causes
- Scale buildup on the heat exchanger thermistor skewing its reading
- Heat exchanger thermistor failing
- Inlet thermistor fault feeding bad data to the control
- Proportional gas valve or water valve fault under-firing the burner
How to fix it — step by step
- Access for the board-level checks below: switch the power OFF at the unit and remove the front cover (a screw at each corner) - the control board and its connectors are behind it. Close the gas and water shut-off valves before disconnecting any gas or water part, and let internal parts cool before handling them
- Turn power OFF and remove connector C on the control board.
- Measure resistance between the #4 (black) and #5 (yellow) wires on connector C — the heat exchanger thermistor circuit should read 7K–23K ohms. → Shop the heat exchanger thermistor at Amazon
- If the reading is out of range, remove the control board bracket, separate the yellow Molex for the heat exchanger thermistor, and measure across the white wires on the female end. → Shop the control board at Amazon
- Clean any scale buildup off the heat exchanger thermistor and retest; if it still reads out of range, replace the heat exchanger thermistor.
- If the thermistor itself tests good but connector C does not, replace the connector C wiring harness; if the code (or code 28) returns with a good thermistor and harness, replace the control board. → Shop the wiring harness at Amazon
- Also check the inlet thermistor (code 31 procedure) and the proportional gas valve / water valve if the low-temperature reading persists.
- Verify the fix: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 05 should stay clear through the whole draw. If it comes back, the fault is still present: recheck the step above whose result was borderline, and treat the part that step points to as the one to replace
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the heat exchanger thermistor.
Shop the heat exchanger thermistor at Amazon
Also tied to this fault: wiring harness - Shop at Amazon; control board - Shop at Amazon
Parts that commonly fix the 05 code
- heat exchanger thermistor$300–$900Shop at Amazon
- wiring harnessShop at Amazon
- control board$100–$300Shop at Amazon
- Tools for this job, if you need them$10–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.