Rheem Water heater 89 Error Code
What the 89 code means
High exhaust temperature detected. The over-temperature limit switch on the secondary heat exchanger has activated because flue gas temperature is too high, so the heater displays 89 and shuts down. This is normally caused by inadequate or wrong gas supply and/or venting.
Likely causes
- Venting problem — blocked, restricted, or incorrectly installed venting holding heat in the unit
- Wrong or inadequate gas supply — wrong gas type, or supply pressure outside specification
- Failed over-temperature limit switch on the secondary heat exchanger
How to fix it — step by step
- Leave the heater off until the cause is found — the limit switch tripped because exhaust temperature exceeded its limit, and restarting without correcting the cause invites repeat trips.
- Inspect the venting end to end — intake and exhaust runs and their terminations — for blockage, restriction, disconnected joints, or incorrect vent installation, and correct what you find (this is the same venting the control monitors under codes 90 and 99).
- Have a qualified technician verify the gas supply: the gas type must match the heater's rating plate, and supply pressure must be within Rheem's specification — Natural Gas 4.0-10.5 in. W.C., LP 8.0-13.0 in. W.C. Correct an inadequate or wrong supply before running the unit.
- With venting and gas proven correct, test the over-temperature limit switch on the secondary heat exchanger and its wiring; a switch that has failed or will not prove out gets replaced. → Shop the over-temperature limit switch at Amazon
- Return the heater to service only after the high-exhaust-temperature cause is corrected. If 89 repeats with correct venting, correct gas supply, and a proven limit switch, the unit needs deeper technician diagnosis — do not keep resetting it.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the over-temperature limit switch.
Parts that commonly fix the 89 code
- over-temperature limit switchShop at Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.