Rheem Water heater Won't Turn On

What this problem usually means

For a heater that is not producing heat or not turning on, the causes are: a blown fuse or tripped breaker, the electric supply off, improper wiring, the manual-reset limit (ECO) opened, the thermostat set too low, and, the one owners miss, the water heater not filled with water or the cold-water supply shutoff closed, either of which stops a heater that has power from ever heating safely. The ECO is Rheem's centrepiece: it is the combination thermostat and temperature-limiting control located above the heating element, in contact with the tank surface; when water temperature goes excessively high it breaks the power circuit to the element and stays open until reset by hand. Rheem's reset procedure is exact — power off, jacket access panel(s) and insulation removed, thermostat protective cover left in place, press the red RESET button, panels back on before power returns — and so is its warning: the cause of the high-temperature condition must be investigated by a qualified technician before the heater goes back into service. On Rheem GAS tanks, 'won't turn on' is the millivolt story instead: dark status light = pilot out and no thermopile power; relight, then judge flame, thermopile and gas control in that order. Rheem tankless models are a separate branch: they need house power for the control, so a dark tankless display starts at the outlet and breaker, and an ignition failure with a live display shows a code (11/12 family) that has its own page.

Likely causes

  1. Blown fuse or tripped breaker, or the electric supply / disconnect switch off — the first listed causes
  2. Manual-reset limit (ECO) opened after an overheat — red RESET button above the upper element, behind the jacket access panel
  3. Heater not filled with water, or the cold-water supply shutoff valve closed
  4. Thermostat set too low, or a failed upper thermostat / upper element (electric tank)
  5. Gas tank: pilot out (no thermopile power, status light dark), weak pilot flame, failed thermopile, or failed gas control
  6. Tankless: no house power to the control, or an ignition lockout displaying its own code

How to fix it — step by step

  1. Work through the checks in order, starting outside the heater: breaker/fuse intact and the disconnect switch ON; then the two water checks owners skip. Run a hot tap: if nothing flows, the cold-water supply shutoff to the heater may be closed, and a tank that was drained and never refilled must be filled (hot tap open until water runs steady) BEFORE power is applied, because powering a dry element destroys it. Only then go inside
  2. Electric branch — the ECO reset, exactly as Rheem writes it: turn the power to the water heater OFF; remove the jacket access panel(s) and insulation (the thermostat protective cover should NOT be removed); press the red RESET button — it sits on the combination thermostat/limit control above the upper heating element, against the tank; replace the insulation and access panel(s) BEFORE turning the power back on. A button that clicks home had tripped → Shop the temperature limiting control (eco) at Amazon → Shop the upper heating element at Amazon
  3. Read the ECO result with this warning attached: the ECO only opens when the water got excessively hot, and the cause must be investigated by a qualified service technician before the heater returns to service — the usual causes are a thermostat stuck closed or an element shorted to the tank. One reset that holds for days after a known one-off (e.g. a long power interruption during a draw) is a result; a reset that trips again is the diagnosis — upper thermostat or element — and it goes to the technician with that note
  4. Electric branch — ECO untripped and still no heat: power is proven to the upper control, so the remaining suspects are the upper thermostat (set too low is Rheem's benign version — check the setting while the panel is open) and the upper heating element behind the same panel. No hot water at all = upper circuit; a short burst of hot then cold = the LOWER element/thermostat instead, and the upper circuit is cleared. Element and thermostat testing is line-voltage technician work; the branch result is the pinpoint
  5. Gas branch — relight by the lighting instructions on the tank: knob to PILOT, hold in, piezo igniter until the pilot lights, keep holding until the status light blinks (the thermopile — the generator tip standing in the pilot flame inside the burner compartment behind the outer door — needs the flame's heat to make the control's millivolt power), then set the temperature and confirm the main burner fires. Pilot that won't light or won't stay lit: judge the flame — steady, blue, enveloping the thermopile tip. Weak or wandering = clogged pilot orifice or poor draft. Good flame, no blinking light = thermopile output test (millivolts, technician); failed thermopile is replaced with the pilot assembly, and a proven thermopile with a dead control condemns the gas control valve
  6. Tankless branch: the control runs on house power — test the outlet, check the breaker, and power-cycle once. A display that lights and shows an ignition code (11 = no ignition, 12 = flame failure family) is not a no-power fault: note the code and work its page. A display that stays dark with the outlet proven is a failed control board — the technician's pinpoint, with the model from the unit's side label
  7. Verify over a full recovery: burner or elements running, hot water at the taps, and no repeat ECO trip or pilot dropout over the next days. Record which branch fixed it — breaker, ECO click, pilot, or code — because a recurrence names its part from that record

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Typical pro repair $228–$1,017

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Rheem Water heater problems