Rheem Water heater 31 Error Code
What the 31 code means
Inlet thermistor malfunction. The control detected an error in the inlet thermistor circuit — open, shorted, or reading out of range — and shut the heater down because it cannot trust the temperature it is controlling to.
Likely causes
- Scale buildup or debris on the inlet thermistor skewing its reading
- Failed inlet thermistor
- Damaged connector C wiring harness
- Failed control board
How to fix it — step by step
- Access for the board-level checks below: switch the power OFF at the unit and remove the front cover (a screw at each corner) - the control board and its connectors are behind it. Close the gas and water shut-off valves before disconnecting any gas or water part, and let internal parts cool before handling them
- Turn power OFF and remove connector C on the control board.
- Measure resistance on connector C between the #4 wire (Black) & #7 wire (White): 7K–23K ohms is normal.
- If out of range, remove the control board bracket to reach the inlet thermistor, separate its white Molex, and measure resistance directly at the sensor. → Shop the inlet thermistor at Amazon → Shop the control board at Amazon
- Clean scale buildup / debris off the inlet thermistor and retest; replace the inlet thermistor if it stays outside 7K–23K ohms.
- If the sensor tests good but connector C does not, replace the wiring harness for connector C. → Shop the wiring harness at Amazon
- Reinsert connector C and operate the unit; if code 31 appears again with a good sensor and harness, replace the control board.
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 31 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the inlet thermistor.
Shop the inlet thermistor at Amazon
Also tied to this fault: wiring harness - Shop at Amazon; control board - Shop at Amazon
Parts that commonly fix the 31 code
- inlet thermistor$25–$80Shop at Amazon
- wiring harnessShop at Amazon
- control board$100–$300Shop at Amazon
- Tools for this job, if you need them$10–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.