Rheem Water heater 4 flashes

What it should look like on your machine

then it repeats

4 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

High water temperature limit tripped. The status light blinks red four times every three seconds: the combination gas control shut the burner down because tank water temperature exceeded the high limit.

Likely causes

  1. Thermostat failed and overheated the tank
  2. Gas control (thermostat) temperature sensing failure
  3. Sediment-insulated tank causing localized overheating

How to fix it — step by step

  1. Do not keep resetting and running the heater — an overheated tank is a scald and pressure hazard; leave the control off and let the water cool.
  2. Locate the suspect part: the combination gas control valve (thermostat) is the large control mounted on the front of the tank, low down, with the temperature knob on its face and its temperature-sensing probe extending into the tank from its back. Access is external — the control is on the outside of the tank; nothing is opened to reach it, but replacing it means draining the tank and breaking gas connections (below).
  3. Pinpoint before replacing: the technician verifies actual tank water temperature with a thermometer against the setpoint — water genuinely over temperature with the burner shut down late points to the control's sensing/ shutoff failing; normal actual temperature with a 4-flash code points to the sensing probe misreading. Either result condemns the gas control, but the first also requires the sediment check below.
  4. Replace the gas control valve/thermostat (A.O. Smith gas manual procedure, same threaded combination-control design): knob to OFF, gas off at the manual shut-off, drain the heater, disconnect the igniter wire and the red (+) and white (-) thermopile wires with needle-nose pliers, disconnect the pilot tube (7/16 in. wrench) and manifold tube (3/4 in. wrench; LP uses left-hand threads) at the control, disconnect the ground joint union and remaining gas pipe, then thread a 4 in. section of gas pipe into the inlet and use it — never a pipe wrench on the body — to turn the control counterclockwise out of the tank. Fit the new control in reverse with approved Teflon tape/pipe compound on the fitting that screws into the tank, do not overtighten, and remove the pilot ferrule nut from the new control. → Shop the gas control valve (thermostat) at Amazon
  5. Turn the main gas on and leak-test every gas connection with approved noncorrosive leak-detection solution (bubbles mean a leak — correct it), refill the tank completely before lighting, light the pilot and main burner per the label, and leak-test the manifold and pilot connections again with the burner lit.
  6. Have the technician check for heavy sediment in the tank bottom and flush the tank if present before the heater returns to service — sediment-insulated hot spots can drive this code.
  7. Tell the technician: 4 flashes high-limit trip, the actual measured water temperature versus setpoint, and whether sediment was found. What this job involves: gas-line disconnection, tank draining and a threaded-in control replacement with leak testing — licensed gas work in most jurisdictions.
  8. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Typical pro repair $228–$1,017
  • gas control valve (thermostat)$115–$500Shop at Amazon
  • Tools for this job, if you need them$5–$65

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Rheem Water heater problems

See all Rheem water heater codes & guides →