Rheem Water heater 24 Error Code
What the 24 code means
DIP switch malfunction signal generated from the controller: the UP/DOWN buttons on the built-in controller or remote controller were pressed for more than 20 seconds, and the control reports it as an error.
Likely causes
- Buttons held down accidentally (cleaning, bumped controller)
- Damaged or loose remote controller wiring
- Failed built-in controller or remote controller
How to fix it — step by step
- Find both ends of the remote wiring before touching anything: the remote controller itself is the wall-mounted unit with the UP/DOWN buttons (fitted wherever it was installed, often near the heater), and its wires land at the bottom of the water heater — the remote control connection terminals are on the bottom of the unit under a white plastic connection cover held by one screw. There are no remote terminals inside the heater, and the front panel does not come off for this job.
- Visually inspect the remote control wiring for damage or loose connections along its run and at both ends: at the heater, loosen the one screw on the white connection cover at the bottom of the unit, lift the cover, and check the two terminal screws are tight (the terminals are not polarity-sensitive); at the wall remote, check the wires are firmly landed on the terminals on its back.
- Turn power OFF and unplug the unit from its power source before disconnecting any wire — Do not connect or disconnect the remote or its wiring while the heater has power applied.
- Run Rheem's isolation test (SVC 820): turn the water off, disconnect the remote control wires at the bottom-of-unit terminals, restore power, and retry operation without the remote connected, resetting with the MIN and MAX buttons on the control board if the code needs clearing. Read the result: if code 24 does not return with the remote disconnected, the fault is in the remote controller or its cable — go to the replacement step. If 24 returns with the remote still disconnected and the unit verified electrically grounded, the fault is inside the unit's control, not the remote — stop here and book qualified service for the control board rather than replacing the remote on speculation.
- Replace a proven-failed remote controller: with power still off, loosen the bottom-centre set screw on the wall remote, pivot the bottom of the remote away from the wall, and lift it up off the hooks of its metal wall mounting plate. Move the two wires to the terminals on the back of the new remote (polarity does not matter), set the new remote onto the mounting plate hooks, pivot it flat, and refit and tighten the bottom set screw. At the heater, land the wires back on the bottom-of-unit terminals, hand-tighten the terminal screws, and refit the white connection cover with its one screw.
- Plug the unit back in, turn power ON, turn the water back on, and attempt operation without holding the UP/DOWN buttons — a button held for more than 20 seconds is what generates this code, so a brief press only.
- Verify with a normal hot-water call: the heater fires, delivers the set temperature, and code 24 does not return. If 24 recurs with the new remote fitted and no button held, the remote was not the cause — the built-in controller/control board is the remaining suspect and is qualified-service work.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the remote controller.
Parts that commonly fix the 24 code
- remote controllerShop at Amazon
- Tools for this job, if you need them$10–$20
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number