Rheem Water heater 28 Error Code

What the 28 code means

Low heat exchanger temperature detected (error code). The heat exchanger thermistor kept reading low temperature after warning code 05 was displayed, so the control shut the heater down.

Likely causes

  1. Scale buildup on the heat exchanger thermistor
  2. Failed heat exchanger thermistor
  3. Damaged connector C wiring harness
  4. Failed control board

How to fix it — step by step

  1. Access for the board-level checks below: switch the power OFF at the unit and remove the front cover (a screw at each corner) - the control board and its connectors are behind it. Close the gas and water shut-off valves before disconnecting any gas or water part, and let internal parts cool before handling them
  2. Turn power OFF and remove connector C on the control board; measure resistance between the #4 (black) and #5 (yellow) wires — 7K–23K ohms is normal.
  3. If out of range, access the heat exchanger thermistor behind the control board bracket, separate its yellow Molex, and measure across the white wires on the female end. → Shop the heat exchanger thermistor at Amazon → Shop the control board at Amazon
  4. Clean scale from the thermistor and retest; replace the heat exchanger thermistor if it remains out of the 7K–23K ohm range.
  5. If the thermistor tests good, reconnect it and re-measure at connector C; a bad reading there with a good thermistor means replace the wiring harness for connector C. → Shop the wiring harness at Amazon
  6. Reinsert connector C and operate the unit; if code 28 appears again with a good thermistor and harness, replace the control board.
  7. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 28 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 28 code

Parts run $100–$900Typical pro repair $228–$1,017

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.